Lennox Hearth ADAGIO-EN User Manual

Page 34

Advertising
background image

34

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

34

Step 6. Refer to Figure 57 and remove the

pilot hood assembly to access the hexed pilot

orifice. Remove and replace the orifice with

the one provided with the kit.

Step 7. (Refer to Figure 55 on Page 33 and
Figure 58)

VERIFY THE PROPER ORIFICE SIZE BE-

FORE INSTALLING IT.

A. Remove the orifice from the manifold and

replace it with the one provided in the kit.

See Table 9 for orifice sizes for natural and

propane models. Figure 58 illustrates the

orifice. Use pipe joint compound or Teflon

tape on all pipe fittings before installing

(ensure propane resistant compounds are

used in propane applications, do not use

pipe joint compounds on flare fittings).

SIT Millivolt Gas
Valve Shown

Pressure

Regulator

Remove

These

Components

Figure 56

Millivolt & Electronic Gas Valves

HI

LO

SIT Electronic Gas Valve

Pressure

Regulator

SIT Millivolt Pilot Assembly Shown

Figure 57

Pilot
Orifice

Thermopile
(on millivolt
pilot assem-
blies only)

Millivolt & Electronic Pilot Assemblies

SIT Electronic Pilot

Pilot
Orifice

B. Retrieve the burner and slide the venturi

tube over the orifice (see Figure 55). Set

the burner assembly into its position and

secure it.

Step 8. Reassemble the remaining components
by reversing the procedures outlined in the
preceding steps.

Step 9. Attach the conversion label provided
in the conversion kit to the rating plate on the
appliance.

Figure 58 - Burner Orifice

Step 10. Turn on gas supply and test for gas
leaks. See Test All Connections For Gas Leaks

on Page 25.

Step 11. Attach manometer to the manifold

side pressure test fitting and verify manifold

pressure reads 3.5 inches water column (0.87

kPa) for natural gas, and 10.0 inches water

column (2.49 kPa) for propane gas.

ALWAYS TEST PRESSURES WITH THE VALVE

REGULATOR CONTROL AT THE HIGHEST

SETTING.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Series

Nat.Gas

drill size (inches)

Propane

drill size (inches)

ADAGIO-MN

.067"
(#51)

-------------

ADAGIO-MP

-------------

.042"
(#58)

ADAGIO-EN

.067"

(#51)

-------------

ADAGIO-EP

if field converted

-------------

.042"
(#58)

Table 9