Lennox Hearth ADAGIO-EN User Manual

Page 21

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

21

V

H

H 1

Wall Firestop/Spacer

(SV4.5HF)

Wall Firestop/Spacer

(SV4.5HF)

When using Secure Flex,

use Firestop/Spacer

SF4.5HF.

Ceiling

Firestop/Spacer

(SV4.5VF)

Note - When using

Secure Flex

TM

, use

Firestop/Spacer SF4.5VF.

Table E

H

+ H

1

Maximum

V Minimum

feet

(meter)

feet

(meter)

3

(0.914)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

V +

H

+ H

1

= 40 feet (12.2 m) Max.

H

+ H

1

= 20 feet (6.096 m) Max.

Figure 32

- Top Vent - TWO 90 DEGREE ELBOWS

Square termination (SV4.5HT-2) shown.

See Table 8 on Page 20 as an aid in venting

component selection for a particular range of

exterior wall thicknesses.

HORIZONTAL VENT FIGURES / TABLES (CONTINUED)

Example: If 20 feet of (H + H

1

) horizontal vent run is needed,

then 4 feet minimum of (V) vertical vent will be required.

This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V)

vertical, you are allowed 5 feet of (H+ H

1

) horizontal run, up

to a maximum horizontal run of 20 feet.

An elbow is acceptable as 1 foot of vertical rise except where

an elbow is the only vertical component in the system. See

Figure 30.

V

H

H 1

V 1

Wall Firestop/Spacer

(SV4.5HF)

Ceiling

Firestop/Spacer

(SV4.5VF)

When using Secure Flex,

use Firestop/Spacer

SF4.5VF.

When using Secure

Flex, use Firestop/Spacer

SF4.5HF.

Wall Firestop/Spacer

(SV4.5HF)

Example: If 20 feet total (H+H

1

) horizontal vent

run is needed, then 4 feet minimum of (V) vertical

vent will be required.
This table shows a 1(V) to 5(H) ratio. For every 1

foot of (V) vertical, you are allowed 5 feet of (H+

H

1

) horizontal run, up to a maximum horizontal

run of 20 feet.
An elbow is acceptable as 1 foot of vertical rise except

where an elbow is the only vertical component in

the system. See Figure 30.

Figure 33

- Top Vent - THREE 90 DEGREE ELBOWS

See Table 8 on Page

20 as an aid in venting

component selection for

a particular range of exte-

rior wall thicknesses.

Table F

H

+ H

1

Maximum

V Minimum

feet

(meter)

feet

(meter)

5

(1.524)

Elbow Only

5

(1.524)

1

(0.305)

10

(3.048)

2

(0.610)

15

(4.572)

3

(0.914)

20

(6.096)

4

(1.219)

H

+ H

1

= 20 feet (6.096 m) Max.

V

+ V

1

+

H

+ H

1

= 40 feet (12.192 m) Max.

Square termination

(SV4.5HT-2) shown.