Caution, Safety / listing label - model profile, Numéro de sêriê/serial wh – Lennox Hearth WHITFIELD 30 FS-2 User Manual

Page 43

Advertising
background image

43

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

INTERIOR VERTICAL FLUE

INSTALLATION

HORIZONTAL FLUE-DIRECTLY THROUGH WALL

INSTALLATION

MANUFACTURED (MOBILE) HOME OR RESIDENTIAL INSTALLATION

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

INSTALLED AS

FREESTANDING STOVE

SIDEWALL TO UNIT

A*

6”/153 MM

6”/153 MM

BACKWALL TO UNIT

B

1”/26 MM

9”/229 MM

CORNER TO UNIT

C

1”/26 MM

1”/26 MM

ALCOVE TO FUEL HOPPER

D

6”/153 MM

6”/153 MM

DEPTH OF ALCOVE

E

16”/407 MM

N/A

FLUE TO WALL

F

3”/77MM

3”/77 MM

G. SIDE WALL

6”/153 MM

H. SIDE TRIM

1”/26 MM

I. TOP TRIM

1”/26 MM

J. ADJACENT

WALL

18”/458 MM

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION
INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER FIREPLACE. SEE LOCAL BUILDING CODE AND MANUFACTURER’S
INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COM-
BUSTIBLE WALL OR CEILING. THIS PELLET FIRED APPLIANCE HAS BEEN TESTED AND LISTED
FOR USE IN MANUFACTURED (MOBILE) HOMES IN ACCORDANCE WITH OREGON
ADMINISTRATIVE RULES 814-23-900 THROUGH 814-23-9O9.

OPERATE ONLY WITH FIREBRICKS IN PLACE. OPERATE ONLY WITH VIEWING DOOR AND ASH
REMOVAL DOOR CLOSED. INSPECT FLUE FREQUENTLY. CLEAN HEAT EXCHANGER AND FLUE
FREQUENTLY TO PREVENT ACCUMULATION OF SOOT. THE HEATER AND FLUE MUST BE IN
GOOD CONDITION. REQUIRED COMPONENTS: DAMPER SEALING PLATE FOR INSERT INSTAL-
LATIONS. USE 3”/75MM OR 4”/100MM MODEL PL CHIMNEY COMPONENTS. KEEP FURNISH-
INGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.

ELECTRICAL RATING: 115V 60Hz Less than 10 Amp
FUEL INPUT RATING: 4.5 Lbs./Hr. Max.

ROUTINE MAINTENANCE REMINDER

FREQUENCY OF CLEANING AND MAINTENANCE OF YOUR STOVE
DEPENDS ON THE ASH CONTENT OF THE PELLETS YOU BURN.
CHECK THE FOLLOWING PARTS OF YOUR STOVE WEEKLY FOR THE
FIRST MONTH TO DETERMINE CLEANING:

A. BURN GRATE
B. HEAT EXCHANGER TUBES
C. ASH TRAPS AND ASH PAN

SEE YOUR MANUAL AND/DEALER FOR MORE INFORMATION.

F

B

A

BACK WALL

J

G

I

H

ADJ

A

CENT SIDE

W
A

LL

INSERT OR BUILT-IN

E

D

D

B

ALCOVE BACK WALL

F

C

C

ADJACENT WALL

ADJ

A

CENT W

A

LL

K

K

K

K

INSTALLED AS AN INSERT

CAUTION:

HOT SUR-

FACES WHILE IN OPERA-
TION. DO NOT TOUCH. CON-
TACT MAY CAUSE SKIN
BURNS. KEEP CHILDREN,
COMBUSTIBLE MATERIAL

AND FURNISHINGS A CONSIDERABLE DIS-
TANCE AWAY. SEE NAMEPLATE AND
INSTRUCTIONS. TYPE OF FUEL: PEL-
LETIZED WOOD FUEL ONLY.

DO NOT REMOVE THIS LABEL

60027304 REV E

PROFILE 30-2

FREESTAND

INSERT

LISTED ROOM HEATER. PELLETIZED WOOD FUEL TYPE. ALSO
FOR USE IN MANUFACTURED (MOBILE) HOME, AND AS AN
INSERT FOR MASONRY FIREPLACES AND FACTORY BUILT
FIREPLACES, OR AS BUILT IN. MODEL: PROFILE 30-2, TESTED
TO: UL 1482 / ULC-S627 / ULC-S628 REPORT NO: 5515 (DEC.
1991) ASTME1509 REPORT NO: 476-1244 (MAR. 1996).

COMBUSTIBLE FLOOR MUST BE PROTECTED BY A
3/8" (10MM) MINIMUM MILLBOARD OR EQUIVALENT
NON-COMBUSTIBLE MATERIAL IN THE USA AND
CANADA EXTENDING BENEATH THE HEATER AND TO
THE FRONT AND SIDES AS INDICATED OR TO THE
NEAREST PERMITTED COMBUSTIBLE MATERIAL
(K=6" / 150MM).

USE 3"/75MM / MODEL PL CHIMNEY COMPONENTS OR LISTED SINGLE
WALL CHIMNEY LINER. SEAL THE AREA BETWEEN THE FIREPLACE DAMPER
AND THE INSERT FLUE. MAY BE INSTALLED IN A MASONRY FIREPLACE
THAT MEETS NATIONAL AND LOCAL BUILDING CODE REQUIREMENTS. (UBC
37 OR ULC S628) DO NOT REMOVE BRICKS OR MORTAR. MAY BE
INSTALLED IN A FACTORY BUILT FIREPLACE. (UL 127 OR ULC S610) DO NOT
ALTER OR MODIFY THE FIREPLACE. REFER TO OWNERS MANUAL FOR
SPECIFIC INSTALLATION REQUIREMENTS. DO NOT ROUTE CORD BENEATH
OR OVER APPLIANCE. THE INSERT MODEL MAY BE FRAMED INTO A WALL
USING ZERO CLEARANCE KIT, CAT. NO. H0416.

UTILISER DES COMPOSANTS DE CHEMINÉE PL DE 3 po/75 MM OU UNE DOU-
BLURE DE CHEMINÉE MURALE SIMPLE. SCELLER L’ENDROIT SITUÉ ENTRE LE
REGISTRE DU FOYER ET LE CONDUIT DE FUMÉE DU FOYER ENCASTRABLE. PEUT
ÊTRE INSTALLÉ DANS UN FOYER DE MAÇONNERIE QUI EST CONFORME AUX
REGLEMENTS DU CODE DU BÂTIMENT LOCAL ET NATIONAL. (UBC 37 OR ULC
S628) NE PAS ENLEVER, LES BRIQUES OU LE MORTIER. PEUT ÊTRE INSTALLÉ
DANS UN FOYER FABRIQUÉ EN USINE. (UL 127 OR ULC S610) NE PAS ALTERER
OU MODIFIER LE FOYER. CONSULTER LE GUIDE DU PROPRIÉTAIRE POUR
CONNAITRE LES EXIGENCES PRÉCISES D’INSTALLATION. NE PAS ACHEMINER LE
CORDON SOUS L’APPAREIL OU AU-DESSUS DE CELUI-CI. LE FOYER
ENCASTRABLE PEUT ÊTRE ENCADRÉ DANS UN MUR À L’AIDE DU NÉCESSAIRE
SANS DÉGAGEMENT, NO DE CAT. H0416.

MUR LATÉRAL ADJACENT

NUMÉRO DE SÊRIÊ/SERIAL WH-

PROFILE 30-2

A* ON RIGHT SIDE OF UNIT (AS VIEWED FROM FRONT), MAINTAIN A 5"
MINIMUM CLEARANCE TO ALLOW FOR PROPER DAMPER OPERATION.

A* Maintenir un dégagement minimum de 5 po sur le côté droit de
l’appareil (lorsque vous le regardez de l’avant).

*

Manufactured Listee:

Lennox Hearth Products; 1110 W. Taft Ave.;

Orange CA USA

Manufactured At: Juarez, Mexico

Product of Mexico

Listee De Fabricant:

Lennox Hearth Products; 1110 W. Taft Ave.;

Orange CA USA

Construit À: Juarez, Mexico

Produit De Mexique

SAFETY / LISTING LABEL - MODEL PROFILE

®

30 FS-2 AND PROFILE 30 INS-2

Advertising
This manual is related to the following products: