CLEARANCES AND HEARTH PROTECTION - INSERT

Masonry And Factory Built Fireplaces

Profi le 30 INS-2

The model Profi le 30 INS-2 is approved for installation into a solid fuel
burning fi replace, either a masonry fi replace (built to UBC 37 or ULC S628
standards) or an approved factory-built / zero clearance fi replace (built
to UL 127 or ULC S610 standards). See Pages 17 and 18 for additional
information on venting.

Minimum Fireplace Firebox Size
Height ...............................................20-1/8” (512 mm)
Width @ Front ...................................32” (814 mm)
(extends back 1-1/2”)
Width @ back ...................................24-5/8” (626 mm)
Depth ................................................17-3/4” (452 mm)

Recommended
clearance zone
from the front of
the appliance to
combustibles is 4
feet minimum.

Clean-Out
Tee

17-3/4”

24-5/8”

32”

Figure 6 - Fireplace Firebox Minimum Size, Insert

Profi le

30-2 INS

(provided in accessory package)

Model Profi le

®

30 INS-2

In the USA and Canada, the area below and directly in front of the Profi le
30 INS-2 fi replace insert must be an approved fi replace hearth or protected
by a non-combustible hearth / fl oor protector with a minimum thickness
of 3/8” which has a thermal conductivity of k (per inch) = .84 or lower
value (better thermal protection) or resistance of r (per inch) = 1.19 or
higher value. See Floor Protection / Hearth Extension Using Alternate
Material As Floor Protector
on Page 5 which explains minimum thermal
protection requirements.

The protected area must extend 6” to the front of the face of the Profi le
30 INS-2.

Profi le

30-2 INS

Top View

Trim

Side Wall

A

C

B

Figure 5 - Clearances, Insert

Profi le 30 INS-2

A - Insert to side wall

6” (153 mm)

B - Insert to side trim

1” (26 mm)

C - Hearth extension

6” (153 mm)

D - Insert to mantel

18” (458 mm)

E - Insert to top trim

1” (26 mm)

Table 4 -

Minimum Clearances To Combustibles

When installing the
Profi le 30 INS-2 into a
factory built fi replace or
heatform, the air fl ow
within and around the
fi replace shall not be
altered by the installa-
tion of the insert (i.e.
DO NOT BLOCK louvers
or cooling air inlet or
outlet ports, circulating
air chambers in a steel
fi replace liner or metal heat circulator). The factory built fi rebox must
accept the insert without modifi cation other than removing bolted or
screwed together pieces such as smoke shelf / defl ectors, ash lips,
screen or door tracks and damper assemblies. Any fi replace compo-
nent, which is removed, must be retained so they can be reinstalled
to restore the fi replace to its original operating condition. The removal
of any part must not alter the integrity of the outer shell of the pre-
engineered fi replace cabinet in any way. A Warning Label (provided
with appliance) must be installed in the fi replace fi rebox so that it shall
be visible upon removal of the fi replace insert (Warning Label shown
in gray above). Use RTV high Temperature Silicone as an adhesive to
affi x the warning label.

W A R N I N G

THIS FIREPLACE HAS BEEN ALTERED TO

ACCOMMODATE A FIREPLACE INSERT AND

SHOULD BE INSPECTED BY A QUALIFIED

PERSON PRIOR TO RE-USE AS A

CONVENTIONAL FIREPLACE.

IF THIS FIREPLACE INSERT IS BEING

INSTALLED INTO A FACTORY BUILT FIREPLACE,

THIS LABEL MUST BE PERMANENTLY

ATTACHED TO THE FIREBOX OF THE

FACTORY BUILT FIREPLACE.

Top View

FIREPLACE WARNING LABEL

Hearth / Floor

Protection

Figure 7 - Mantel and Trim Clearances, Insert

Side View

Trim

Mantel

D

E

Profi le

®

30-2 INS