7 − Install the filters and the filter access door.

ОО

ОО

ОО

ОООО

ОООО

ОООО

SIDE VIEW

AIR

FLOW

2-3/4

(70)

29-1/4 (743)

27-1/4 (692)

Furnace

Opening

26-1/8 (664) x 50-5/8 (1286)

Floor Opening

1

(25)

1

(25)

26-1/4 (667)

Filter Box

Opening

4-3/4
(121)

BOTTOM RETURN AIR FILTER BOX INSTALLATION

ADHESIVE-
BACKED
FOAM TAPE

UNIT

FILTER
BOX

PLATFORM

RETURN AIR PLENUM

INCHES (mm)

FIGURE 5

WARNING

Improper installation of the furnace can result in per-
sonal injury or death. Combustion and flue products
must never be allowed to enter the return air system
or the living space. Use screws and joint tape to seal
the return air system to the furnace.
In platform installations with bottom return air, the
furnace should be sealed airtight to the return air ple-
num. A door must never be used as a portion of the
return air duct system. The base must provide a
stable support and an airtight seal to the furnace. Al-
low absolutely no sagging, cracks, gaps, etc.
The return and supply air duct systems must never
be connected to or from other heating devices such
as a fireplace or stove, etc. Fire, explosion, carbon
monoxide poisoning, personal injury and/or proper-
ty damage could result.