Explation for micom circuit – LG SXS GR-P257/L257 User Manual

Page 31

Advertising
background image

1-5. Dispenser operation circuit

(1)

GR-P227/L227/P257/L257

1) Check load driving status

2) Lever Switch sensing circuit

EXPLATION FOR MICOM CIRCUIT

- 29 -

Measuring part

Lever S/W

IC1(Micom) (No. 16)

On

OFF

5V

0 V

(60 Hz)

5 V

Measuring part

IC7-15

IC7-14

IC7-13

IC7-12

IC7-11

Status

ON

Within 1 V

OFF

12 V

Type of Load

GEARED

MOTOR

SOLENOID

CUBE

PILOT

VALVE

WATER VALVE

WATER

SOLENOID

DISPENSER

Advertising