TROUBLE

D

IAGNOSIS

-6
5-

Problems

Causes

Checks

Measures

Remarks

Sound "Burping" It happens when refrigerant expands - Check the sound of refrigerant at the

- Check the restrainer attached on the

(almost the same at the end of capillary tube.

initial installation.

evaporator and capillary tube weld

as animals crying

- Check the sound when the refrigerator

joints and attach another restrainer.

sound).

starts operation after forced defrosting.

- If it is continuous and servere, insert

- Check the restrainer attachment

capillary tube again (depth:15±3mm)

conditions on the evaporator and

- Fasten the capillary tube to suction

capillary tube weld joints.

pipes or detach in the compressor

compartment.

- Explain the principles of freezing

cycles.

Water boiling or

It happens when refrigerant passes

- Check the sound when compressor is

- Explain the principles of freezing cycles

flowing sound.

orifice in accumulator internal pipes by

turned on.

and refrigerant flowing phenomenon by

the pressure difference between

- Check the sound when compressor is

internal pressure difference.

condenser and evaporator.

turned off.

- If sound is servere, wrap the

accumulator with foam and restrainer.

Sound of whistle

When door closes, the internal pressure

- Check the sound by opening and

- Broaden the cap of discharge hose for

when door

of the refrigerator decreases sharply

closing the refrigerator or freezer doors.

defrosting in the compressor

closes.

below atomosphere and sucks air into

compartment.

the refrigerator, making the whistle

- Seal the gap with sealant between out

sound.

and inner cases of hinge in door.