background image

TROUBLE

D

IAGNOSIS

-7
1-

Problems

Symptom

Causes

Checks

Measures

Remarks

Defective

Buzzer rings

Trouble mode indication.

Check trouble diagnosis function.

Repair troubles

Refer to mode

display button.

but key does

indication in

not sense even

function

button is

explanations.

pressed.

Door Buzzer

Buzzer

Defective connecting lead wire from

Check lead wire associated with door

Repair lead wire.

Check model

continuously

main PCB to door switch.

switch.

with dispenser.

rings or door

Defective freezer compartment door

Refer to door switch in parts repair

Replace Freezer

opening alarm

switch parts.

guide.

compartment door

does not work.

switch.

Bad water/ice

Ice and water

Defective connecting lead wire from

Check Lead Wire associated with lever

Repair lead wire.

dispenser.

are not

Main PCB to lever switch.

switch with a tester.

dispensed.

Defective lever switch parts

Refer to door switch in parts repair guide. Replace lever switch.

Defective photo coupler IC parts.

Check voltage change at photo coupler

Replace photo

output terminals with lever switch

coupler IC or PCB.

pressed. It is OK if voltage change is

between 0V - 5V.

Defective relay associated with ice

Check relay (RY4, RY5, RY12)

Replace defective

dispense (geared motor, cube and

with a tester.

relay.

dispenser solenoid).

Defective parts associated with ice

Check resistance of parts with a tester.

Replace defective

dispense (geared motor, cube and

parts.

dispenser solenoid).

Defective relay associated with water

Check relay (RY7) with a tester

Replace defective

dispense.

relay.

Defective parts associated with water

Check resistance of parts with a tester.

Replace defective

dispenser.

parts.