Trouble d iagnosis – LG SXS GR-P257/L257 User Manual

Page 72

Advertising
background image

TROUBLE

D

IAGNOSIS

-7
0-

Problems

Symptom

Causes

Checks

Measures

Remarks

Bad defrost.

Defrost is not

Defrost lead wire is cut.

Check if defrost lead wire is cut with a

Reconnect Lead

working.

tester.

Wire.

Defective defrost driving relay.

Check the voltage of CON2 (1 and 7)

Replace relay (RY 7

Refer to load

with a tester after pressing main

and RY 3) or PCB.

driving conditions

PCB test switch twice.

check in circuit

If the voltage is normal then it is OK.

explanation.

Defective defrost sensor parts.

Check the resistance of defrost sensor

Replace defrost

Refer to sensor

with a tester.

sensor.

resistance

characteristic

table of circuit

explanation.

Defective

Buzzer

Defective connecting lead wire from

Check lead wire related to door

Repair lead wire.

buzzer

continuously

main PCB to door switch.

switch with a tester.

rings or door

Defective door switch parts.

Refer to door switch in parts repair

Replace door switch.

opening alarm

guide.

does not work.

Defective

Buzzer does

Key input wire is cut or bad connector

Check input wire with a tester.

Reconnect lead

Refer to display

display button

not ring and

terminal contact in main PCB and

wire and replace or

circuit in circuit

key does not

display PCB connecting lead wire.

directly connect bad

explanation.

sense even

contact terminal to

button is

lead wire.

pressed.

Key is continuously depressed due to

Disassemble frame display and confirm

Adjust or replace

structural interference.

visually.

interfering

structures.

Advertising
This manual is related to the following products: