Trouble diagnosis – LG SXS GR-P257/L257 User Manual

Page 49

Advertising
background image

TROUBLE DIAGNOSIS

- 47 -

CLAIMS.

CAUSES AND CHECK POINTS.

HOW TO CHECK

3. Refrigeration

is weak.

Heater
Sheath

1) Refrigerant Partly leaked.

2) Poor defrosting capacity.

Drain path (pipe) clogged.

Defrost heater does not
generate heat.

Weld joint leak.
Parts leak.

Inject P/U into drain hose.

Foreign materials
penetration.

Cap drain is not disconnected.

Inject through the
hole.
Seal with drain.

P/U lump input.
Screw input.
Other foreign materials
input.

Parts
disconnected.

Wire is cut.

- Lead wire.
- Heating wire.
- Contact point

between heating and
electric wire.

Dent by fin evaporator.
Heating wire is corroded

- Water penetration.

Bad terminal connection.

■ Check visually.

■ Check terminal

Conduction: OK.
No conduction: NG.
If wire is not cut, refer to
resistance.
P=Power
V=Voltage
R=Resistance

V

2

P= —

R

V

2

R= —

P

Advertising