Surge suppression systems, Type ss series – Liebert PanelGuard Extension User Manual

Page 13

Advertising
background image

Surge Suppression Systems

Installation, Operation and Maintenance Manual

11

Liebert TVSS Units SL-22085 Rev 2, 11/2006

Typical Series Connections for Delta (3 Wire + Ground) System

N

G

Phase (s)

Neutral

Neutral

Phase (s)

INPUT

OUTPUT

Transient

Ground

Safety

Ground

Liebert

Active Tracking

Filter System

To

“Protected”

Load (s)

}

Neutral

(required)

Ground

’s

G

Phase (s)

Phase (s)

INPUT

OUTPUT

Transient

Ground

Safety

Ground

Liebert

Active Tracking

Filter System

To

“Protected”

Load (s)

}

Ground

’s

Typical Series Connections for Wye (4 Wire + Ground) or Single Phase (3 Wire + Ground) System

TERMINAL WIRE SIZE RANGE

FILTER CONTINUOUS

PHASE AND

TRANSIENT

SAFETY

CURRENT RATING

NEUTRAL TERMINALS

GROUND TERMINAL

GROUND TERMINAL

30 –100 A

# 14 – 2/0 (1)

# 14 – 2/0 (5)

# 14 - # 4 (4)

225 A

# 6 – 250 kcmil (1)

# 14 – 2/0 (5)

# 10 – 1/0 (4)

400 A

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (4)

800 A

2.75 x .50 Cu Busbar (3)

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (4)

1200 A

(2x) 6.0 x .25 Cu Busbar (3)

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (4)

2000 A

(3x) 6.0 x .25 Cu Busbar (3)

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (2)

4000 A

(5x) 6.0 x .25 Cu Busbar (3)

# 6 – 250 kcmil (2)

# 6 – 250 kcmil (2)

NOTES:
1. Single lug with single connection for Input and Output.

2. Single lug with dual connection for Input and Output.

3. Units must be installed with Busbar(s) only! Wire lugs are not U.L. approved.

4. Single lug with single connection.

5. Single lug with dual connection.

Installation, Operation and Maintenance Manual

18

Liebert TVSS Units SL-22085 Rev 2, 11/2006

Surge Suppression Systems

Type SS Series

L2

L1

N

A

B

C

GND

N

Service Panel For

Loads to be Protected

Phase L1

Phase L2

Dedicated

Disconnect

(Optional)

Disconnect/Main

Breaker For

Panel

Neutral Buss

Service Panel For

Loads to be Protected

Disconnect/Main

Breaker For

Panel

Dedicated

Disconnect

(Optional)

Neutral Buss

Ground Buss

Phase A

Phase B

Phase C

Polycarbonate Window

B

A

C

E

F

D

Type SS Series

Unit

Dimensions (Inches)

Weight

(lbs)

Suggested

Breaker Size

Suggested

Wire Size

(AWG)

Allowable

Breaker

Range

Allowable

Wire Range

A

B

C

D

E

F

1 Phase
3 Phase

13.32
17.32

6.6
9.6

14.75
18.75

10
12

0.32
0.32

26
43

80 A
80 A

#4
#4

15A – 175A
15A – 175A

#14 – 2/O
#14 – 2/O

15.32
19.32

Liebert Interceptor II Printer S13 13

12/29/06 1:37:59 PM