NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • INSTALLATION INSTRUCTIONS

MANUALLY-RESET BLOCKED FLUE SAFETY

SWITCH

This appliance is equipped with a manually-reset

blocked flue safety switch. Refer to Figure 26

for its location. If during appliance operation,

the flame goes out (independently of the burner

on/off wall switch), it may be due to the opera-

tion of this safety limit switch. First allow the

appliance to cool. Then reset the safety switch

by pushing the red reset button.

This reset button is located on the back of the

limit switch, between the wire terminals (see

Detail A of Figure 26).

The appliance should then relight and remain

lit. If this does not occur, turn off the appli-

ance and call a qualified service technician.

Figure 26

Detail A

Manual Reset

Limit Switch

Lintel

Extension

Right Side

Refractory Panel

Reset

Button

Wire

Terminals

Figure 28

Replace logs if removed for pilot inspection.

To light the burner; rotate the gas valve control

knob counterclockwise to the “ON” position

(“ON” will be to the right hand side of the valve).

Turn “ON” the remote wall switch.

Electronic Appliance Checkout

To light the burner, turn ‘ON’ the optional remote

wall switch. Ensure the igniter lights the pilot.

The pilot flame should engulf the flame rod as

shown in Figure 28.

Figure 27

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting

or floating. Flame should be blue in color with

traces of orange at the outer edge.

The top 3/8" (9 mm) at the pilot generator

(thermopile) should be engulfed in the pilot

flame. The flame should project 1" (25 mm)

beyond the hood at all three ports (Figure 27).

3/8" Min

(9 mm)

Hood

Pilot

Nozzels

Igniter Rod

Hood

Igniter Rod

Pilot

Nozzels

Flame

Sensor

Figure 25

Piezo

Igniter

SIT Valve

VERIFYING APPLIANCE OPERATION

Step 9. Checking the System – With gas line

installed run initial system checkout before

closing up the front of the unit. Follow the

pilot lighting instructions provided in the Hom-

eowner's Care and Operation Instructions. For

piezo igniter location see Figure 25 (millivolt

appliances only).

Note: Instructions are also found on the pull

out lighting instructions label attached to the

gas control valve.

When first lighting the appliance, it will take a

few minutes for the line to purge itself of air.

Once purging is complete, the pilot and burner

will light and operate as indicated in the instruc-

tion manual.

Subsequent lightings of the appliance will

not require such purging. Inspect the pilot

flame (remove logs, if necessary, handling

carefully).