NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

REQUIREMENTS FOR THE COMMON-

WEALTH OF MASSACHUSETTS
These fireplaces are approved for installation in

the US state of Massachusetts if the following

additional requirements are met:
• Installation and repair must be done by a

plumber or gas fitter licensed in the Com-

monwealth of Massachusetts.

• The flexible gas line connector used shall not

exceed 36 inches (92 centimeters) in length.

• The individual manual shut-off must be a

T-handle type valve.

Test gauge connections are provided on the front

of the millivolt gas control valves (identified OUT

for the manifold side and IN for inlet pressure side.

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(0.55 kPa)

(Hi) 3.5" WC

(0.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.0" WC

(1.24 kPa)

10.5" WC

(2.62 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.24 kPa)

Table 2

Gas Pressure - All Models

Tables 2 and 3 show the appliances' inlet and

manifold gas pressure requirements:

The appliance and its appliance main gas

valve must be disconnected from the gas

supply piping system during any pressure

testing of that system at test pressures in

excess of 1/2 psi (3.5 kPa).

The appliance must be isolated from the

gas supply piping system by closing its

equipment shutoff valve during any pressure

testing of the gas supply piping system at

test pressures equal to or less than 1/2 psi

(3.5 kPa).

Orifice Sizes - Sea Level to High Altitude

(All Models)

These appliances are tested and approved for

installation at elevations of 0-4500 feet (0-1372

meters) above sea level using the standard burner

orifice sizes (marked with an "*" in Table 4). For

elevations above 4500 feet, contact your gas

supplier or qualified service technician.

Deration - At higher elevations, the amount

of BTU fuel value delivered must be reduced

by either:

• Using gas that has been derated by the gas

company.

• By changing the burner orifice to a smaller

size as regulated by the local authorities having

jurisdiction and by the (USA) National Fuel Gas

Code NFPA 54/ANSI Z223.1 - latest edition or,

in Canada, the CAN/CGA-B149.1 codes - latest

edition.

Install the appliance according to the regulations

of the local authorities having jurisdiction and,

in the USA, the National Fuel Gas Code NFPA

54 / ANSI Z223.1 - latest edition or, in Canada,

the CAN/CGA-B149.1 - latest edition.

Flame breadth, height and width will diminish

4% for every 1,000 feet of altitude.

In Canada - CAN/CGA-2.17-M91 (R2009) (high

altitude): THE CONVERSION SHALL BE CAR-

RIED OUT BY A MANUFACTURER’S AUTHO-

RIZED REPRESENTATIVE, IN ACCORDANCE

WITH THE REQUIREMENTS OF THE MANU-

FACTURER, PROVINCIAL OR TERRITORIAL

AUTHORITIES HAVING JURISDICTION AND

IN ACCORDANCE WITH THE REQUIREMENTS

OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2

INSTALLATION CODES.

Burner Orifice Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#26 (0.147")

*

H5805 •

#45 (0.082")

*

39L66 •

Table 4

* Standard size installed at factory

• Part /Cat. Number

Figure 1 - - SIT Millivolt Gas Valve

E

A

TPTH

TP

TH

PILO

T

PIL

OT

ON

it

OFF

Inlet Gauge Port

Pilot Adjustment Screw

Manifold Gauge Port

Figure 2 - SIT Electronic Gas Valve

Gas Valve Diagrams

See Figure 1 for Millivolt models and Figure 2

For Electronic Models.

Manifold Pressure Tap

Inlet Pressure Tap

Piezo

Igniter

Main Gas Control Knob

OFF/PILOT/ON