LENNOX HEARTH PRODUCTS • CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • INSTALLATION INSTRUCTIONS

All appliances are equipped with a gas flex line

and shutoff valve attached directly to the gas

control valve. To quickly and easily complete

the gas line routing, use the gas flex line kit.

Step 3. Position the Appliance - Slide the

fireplace into prepared framing or position

fireplace in its final position and frame later.

Refer to fireplace drawings and specifications

on Page 7 for framing dimensions and details.

Framing header may be positioned directly on

the fireplace top spacers.

IMPORTANT: UNDER NO CIRCUMSTANCES

CAN THE FIREPLACE TOP SPACERS (refer

to Figure 10) BE REMOVED OR MODIFIED,

NOR MAY YOU NOTCH THE HEADER TO FIT

AROUND OR BE INSTALLED LOWER THAN THE

SPACERS. THE HEADER MAY BE IN DIRECT

CONTACT WITH THE TOP SPACERS BUT MAY

NOT BE SUPPORTED BY THEM.

Fireplace should be secured to side framing

members using the full length 1/2 inch nailing

flanges that are integral to the appliance at each

side. Use 6d nails or equivalent (Figure 10).

WARNING

CONNECTING DIRECTLY TO AN UN-

REGULATED PROPANE (L.P.G). TANK

MAY CAUSE AN ExPLOSION.

An external regulator must be used on all pro-

pane (L.P.G). heaters to reduce the supply tank

pressure to 13" w.c. (maximum). Any copper

tubing used to supply propane (L.P.G). from

the tank must be internally tinned.

IMPORTANT: HOLD GAS VALVE SECURELY TO

PREVENT MOVEMENT WHEN CONNECTING TO

INLET GAS LINE

Figure 11

Step 4. Install the Vent System and

Exterior Termination
Slip a 10" (254 mm) B-Vent system over the

appliance collar (Figure 11) and secure with

four sheetmetal screws (# 8 or larger). Minimum

overall height of the vent system and appliance

must be 12' (3.66 m) vertical (no offset) or 17'

(5.18 m) when an offset up to 45 degrees from

the vertical is used. The lower part of the offset

must not begin less than 3' (0.914 m) above the

top of the fireplace (see Figure 12).
Maximum overall height of the vent system and

appliance should not exceed 40 feet (12.19m).
Install the B-vent system in accordance with

the vent manufacturer's instructions.
CAUTION: THIS APPLIANCE CANNOT BE

VENTED HORIZONTALLY.
Note:
Refer to the vent manufacturers instal-

lation instructions for variations of venting

techniques. If common venting of several units

is contemplated, it should be discussed with an

architect and the local Building Department.

Note: The nailing flanges and the area directly

behind the nailing tabs are exempt from the

clearances described on the fireplace clear-

ance label.

Figure 10

6d Nail or

Equivalent

10

Type B-Vent

Flue Outlet

Collar

Securing

Screws

12 ft.

Minimum

17 ft.

Minimum

45 degrees

max.

3 ft.

Minimum

to Offset

12 ft.

Minimum

17 ft.

Minimum

45 degrees

max.

3 ft.

Minimum

to Offset

Figure 12