Gas conversion kits (continued) – Lennox Hearth Crestline LSBV-3628MN User Manual

Page 19

Advertising
background image

19

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LENNOX HEARTH PRODUCTS • CRESTLINE™ SERIES B-VENT GAS FIREPLACES • 36"/42" LSBV MODELS • INSTALLATION INSTRUCTIONS

Burner Orifice Sizes (all models)

Elevation

Feet (meters)

Natural

Gas

drill size (inches)

Propane

Gas

drill size (inches)

0-4500

(0-1372)

#26 (0.147")

*

H5805 •

#45 (0.082")

*

39L66 •

Table 5

* Standard size installed at factory

• Part /Cat. Number

Figure 33

Figure 34

Step 9. Reassemble all removed components

by reversing the procedures outlined in the

preceding steps. Use pipe joint compound or

Teflon tape on all pipe fittings before installing

(ensure propane resistant compounds are used

in propane applications, do not use pipe joint

compounds on flare fittings).

Step 10. Attach the conversion label provided

in the conversion kit to the rating plate on the

appliance.

Step 11. Turn on gas supply and test for gas

leaks (see Step 6 on Page 8).

Step 5. Millivolt Systems – Attach manometer

to the manifold side pressure test fitting and

verify manifold pressure reads 3.5" water col-

umn (0.87 kPa) for natural gas, and 10.0" water

column (2.49 kPa) for propane gas.

Step 6. See Figure 31 and remove the pilot

hood assembly to access the hexed pilot orifice.

Remove and replace the orifice with the one

provided with the kit.

When reinstalling the igniter assembly, use

extreme care to prevent damage and break-

age. Do not apply any leverage to the igniter

assembly while restoring the retainer clip to

its original position.

All Models

Step 8. Unscrew the orifice from the manifold

and replace it with the one provided with the

kit. See the following table for orifice sizes

for natural and propane models. Figure 34

illustrates the orifice.

Refer to Figure 32 and replace the pilot orifice

as follows: Remove the pilot hood assemble

to access the hexed pilot orifice.

Remove the pilot orifice and replace it with the

one provided with the conversion kit. Reinstall

the pilot assembly by reversing the steps

detailed here.

Pilot

Orifice

Pilot

Orifice

Electronic Appliances

Step 7. SIT Electronic Valves - See Figure

33 and the instructions provided with the

kit. Remove the slotted cap screw, o-ring,

pressure-regulating adjusting screw and spring,

then discard.

Modify the pressure regulator from the kit.

Using a standard tin snip cutting tool, proceed

to trim shoulder off of the regulator.

Install new components and modified pressure

regulator from the kit.

Attach manometer to the manifold side pressure

test fitting and adjust screw until pressure reads

3.5" water column (0.87 kPa) for natural gas, and

10.0" water column (2.49 kPa) for propane gas.

Modified Kit

Pressure Regulator

- After Trim

Remove

These

Components

SIT VALVE

Kit Pressure

Regulator - Before

Trim

Figure 31

Figure 32

Gas Conversion Kits (continued)