Lennox Hearth CAMBRIA 850 User Manual

Page 4

Advertising
background image

Accelerated Combustion

The maximum heat output for the Cambria

fireplace is achieved by burning with the door

closed and the combustion air opened. How-

ever, it will be necessary to reload with wood

every hour. This is the least efficient method

of burning the Cambria fireplace. Use caution

when burning with the combustion air control

wide open. Only burn cordwood in this manner.

Small dry pieces of softwood will burn very

intensely using this method and may damage

the firebox.

Medium Combustion

This is the recommended mode of operating

the Cambria fireplace and should be the one

normally used since it will deposit the least

amount of creosote on the glass and in the

chimney. The combustion air control must be

3/4 closed .The precise setting will depend on

many factors, including chimney length and the

moisture content of the wood.

For instance, a long chimney will necessitate

closing the damper more. To obtain the proper

combustion, close the damper completely, then

open it about 1/4” to 1/2”. Three medium size

pieces of cordwood burning on a bed of hot coals

will burn about 1-2 hours. Softwoods may be

burned using this method but the combustion

time will be substantially reduced.

FOR MAXIMUM HEAT OUTPUT, WE STRONGLY

RECOMMEND THE INSTALLATION OF THE

OPTIONAL HOT AIR DUCTING SYSTEM.

Figure 2 - Accelerated Combustion

Figure 3 - Medium Combustion

Figure 1

Open

Closed

Open

Closed

First Fires

Before using the fireplace make sure to remove

the plastic wrapping on the door. Remove all

remaining glue with mild soap. Make sure the

doors are properly adjusted, thus avoiding color

change to finish due to overheat.

The first 5 or 6 fires should be small fires of short

duration (about 30 to 60 minutes). This will help

cure the refractory bricks. During the first few

fires of this appliance there may be some odor

and smoke due to the curing of the paint, dust

accumulation and burning off of lubricants used

in the manufacturing process. It may set off a

smoke alarm located in the same room. For

this reason the room should be well ventilated

for the first few fires.

HEAT OUTPUT

The Cambria™ fireplace is a mid-efficiency

fireplace. In spite of the heat that the Cambria

fireplace can deliver, it should not replace the

main source of heat in your home. This fireplace

will bring extra warmth and ambiance to your

home by distributing its heat as described further

in the manual.

FOR MAXIMUM HEAT OUTPUT, WE STRONGLY

RECOMMEND THE INSTALLATION OF HOT AIR

DUCTING SYSTEM (See Page 14).

Combustion Control and Chimney

Damper

The Cambria fireplace includes a combustion

air control that sets the flow of air entering

the firebox and control the fire. The fireplace

also includes a chimney damper that is not

a combustion control. The chimney damper

must always be in fully open position when

the fireplace is used and should be closed only

when all ashes are cold.

The chimney damper is controlled by the handle

inside the firebox (see Figure 1-A). It is in closed

position when the handle is visible (front) and

in the open position when not visible (pushed

back). The combustion air damper is controlled

by the lower handle (see Figure 1-B). The control

can be moved from open position at left all the

way to the close position at right.

This air combustion control should be in the

closed position when the fireplace is not in

operation. This will minimize air infiltration.

The combustion air control should be opened

before opening the doors to minimize the

possibility of back draft coming into the

room (see Figure 1-A). Also see Smoking

- Causes and Troubleshooting for more details

(on Page 5).

WARNING: The air combustion control

must be in the open position if the fire-

place is operated with the doors open.

Chimney

Damper

(A)

Open

Back

Closed

Front

Combustion Air

Control (B)

Closed

Open

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

4