GLASS CARE

Glass Replacement

The glass used for the Cambria™ fireplace is

a high temperature ceramic glass (1400°F). If

the glass breaks or cracks, it must be replaced

with an identical ceramic glass. Tempered

glass or ordinary glass will not withstand the

high temperatures of the Cambria fireplace.

Replacement glass should be purchased from

a Lennox Hearth Products dealer (see “Replace-

ment Parts” on Page 25).

Do not operate the unit with cracked or broken

glass.

Glass Cleaning

The Cambria fireplace is designed to keep the

glass clean under normal operating condi-

tions. If the Cambria fireplace is operated

continuously with the combustion air controls

closed, the glass will tend to get dirty unless

the fuel, firebox and glass are maintained at

hot temperatures. To clean the glass, there

are a number of specially designed cleaners

to remove creosote. Your authorized Lennox

Hearth Products dealer can recommend a suit-

able cleaner. Regular household glass cleaners

will not clean creosote. Do not use abrasives

such as steel pads, steel wool or oven cleaner

as they will scratch the glass.

DO NOT USE CHEMICAL GLASS CLEANERS

ON PAINTED SURFACES AS IT MAY CAUSE

THE PAINT TO PEEL.

CAUTION : DO NOT ALLOW WINDOW CLEANER

TO GET IN CONTACT WITH DOOR GASKET OR

PAINT ON FACADE OR DOOR. ONCE CLOSED,

CONTACT OF GLASS CLEANER WITH THE

FIREPLACE FACADE CAN PROVOKE PAINT

PEELING OFF.

Andirons

The Cambria fireplace is equipped with and-

irons designed to keep logs from falling into

the door. It must be replaced only by Lennox

Hearth Products andirons available from your

dealer. No other andirons, log retainer or log

support is sold or recommended by Lennox

Hearth Products.

Gasket Replacement

Remove the doors from the unit (see Door

Installation on Page 6) and lay them on a clean

nonabrasive surface. To replace the gasket, first

remove all of the old gasket and gasket cement.

Make sure that the surface is totally clean before

applying new cement (a high temperature sili-

cone caulking rated at 500°F / 260°C, is suitable)

or adhesion problems may result. Apply gasket

cement to the gasket channel and install the

new gasket. This replacement part is available

from your Lennox Hearth Products dealer in the

dimensions shown in Table 1.