40

8 Bay Frame

Internal and External (minutes)

Load

Load

VA

Watts

1

2

3

4

5

6

7

1

2

3

4

5

6

16,000

11,200

-

-

-

6

-

-

-

24

60

100

120

180

240

15,500

10,850

-

-

-

6

-

-

-

26

63

107

140

195

255

15,000

10,500

-

-

-

6

-

-

-

27

67

114

160

210

270

14,500

10,150

-

-

-

6

-

-

-

28

70

120

180

225

285

14,000

9,800

-

-

-

7

-

-

-

30

73

127

190

240

300

13,500

9,450

-

-

-

7

-

-

-

31

77

135

200

252

320

13,000

9,100

-

-

-

8

-

-

-

32

80

142

210

264

340

12,500

8,750

-

-

-

8

-

-

-

34

85

150

220

276

360

12,000

8,400

-

-

6

9

12

-

-

36

90

157

230

288

375

11,500

8,050

-

-

6

9

13

-

-

38

95

165

240

300

390

11,000

7,700

-

-

6

10

14

-

-

40

100

173

255

320

405

10,500

7,350

-

-

7

10

15

-

-

42

110

180

270

340

420

10,000

7,000

-

-

7

11

18

-

-

45

120

195

285

360

450

9,500

6,650

-

-

8

13

18

-

-

50

130

210

300

390

480

9,000

6,300

-

-

9

14

19

-

-

53

140

225

320

420

510

8,500

5,950

-

-

9

15

20

-

-

57

150

240

340

450

540

8,000

5,600

-

6

10

18

21

26

-

60

160

260

360

480

570

7,500

5,250

-

6

11

18

23

28

-

65

170

280

390

510

600

7,000

4,900

-

7

13

19

25

29

-

70

180

300

420

540

660

6,500

4,550

-

8

14

21

27

30

-

80

200

330

480

600

720

6,000

4,200

-

9

18

24

29

36

-

90

220

360

510

660

810

5,500

3,850

-

10

19

26

30

39

-

100

240

420

540

720

900

5,000

3,500

-

12

20

29

36

43

-

120

270

450

600

810

1,000

4,500

3,150

-

14

24

30

40

46

-

140

300

480

720

900

1,100

4,000

2,800

6

18

26

36

43

49

52

160

360

540

810

1,080

1,200

3,500

2,450

7

19

29

41

48

52

56

180

420

600

900

1,260

1,440

3,000

2,100

9

24

36

46

51

56

62

210

480

720

1,050

1,440

1,620

2,500

1,750

12

29

43

51

56

63

68

240

600

900

1,200

1,620

1,800

2,000

1,400

18

36

50

57

64

68

72

360

720

1,200

1,440

1,800

2,880

1,500

1,050

24

46

56

65

69

73

74

480

900

1,440

2,400

3,000

3,600

1,000

700

36

56

68

73

74

75

78

720

1,440

2,400

3,600

4,320

4,320

900

630

39

59

69

73

75

78

78

900

1,800

3,000

4,320

4,320

4,320

800

560

43

63

72

74

76

78

79

1,080

2,100

3,600

4,320

4,320

4,320

700

490

48

68

73

75

78

79

79

1,260

2,400

4,320

4,320

4,320

4,320

600

420

51

69

74

77

79

79

80

1,440

3,000

4,320

4,320

4,320

4,320

500

350

56

72

75

78

79

80

80

1,440

3,600

4,320

4,320

4,320

4,320

Quantity of

Battery Modules

Quantity of

External Battery Cabinets with charger

Note: Back-up times are in minutes and are based upon resistive loading at an ambient of 25°C, for non-redundant (standard)
configurations. Back-up times for external battery cabinets with chargers include internal battery modules that are equal to the
number of power modules in the UPS frame.

Battery Run Times

Advertising