Lenovo THINKSERVER 392 User Manual

Page 154

Advertising
background image

1. Locate the failing hot-swap redundant power supply module on the rear of your server. Then, press the

release tab

1

in the direction as shown and carefully pull the handle

2

at the same time to slide the

redundant power supply module out of the chassis.

Note: Do not use too much strength. You can first carefully slide the redundant power supply module a
little bit out to release it from the secured position. Then, completely slide it out of the chassis.

Figure 80. Removing a hot-swap redundant power supply module

2. Touch the static-protective package that contains the new hot-swap redundant power supply module

to any unpainted surface on the outside of the server. Then, remove the new hot-swap redundant
power supply module from the package.

142

ThinkServer Hardware Maintenance Manual