WR-210AE

0 dBV

COM

C

24V

0V

H

OUT IN

(0V)

LIN OUT

DC

PRIORITY

REC OUT

0 dBV

COM

C

24V

0V

H

OUT IN

(0V)

LIN OUT

DC

PRIORITY

REC OUT

0 dBV

COM

C

24V

0V

H

OUT IN

(0V)

LIN OUT

DC

PRIORITY

REC OUT

Shielded pair cable

Remote Microphone 1

First priority

(Master)

Remote Microphone 2

Second priority

(Slave 1)

Remote Microphone 3

Third priority

(Slave 2)

Amplifier

ALL CALL

BUS THRU

INS
THRU

INS
IN

INS
THRU

INS
IN

ALL CALL

BUS IN

ALL CALL

BUS THRU

ALL CALL

BUS IN

*1

*2

*3

*3

*1

*2

*2

*3

*4

*4

Individual Priority

Making connection settings

Refer to the following illustration for connecting up to 4 Remote Microphone. And the priority order of Remote Microphones
depends on the order, in which they are connected to the Mixing Power Amplifier.
Connect the high priority Remote Microphone’s priority output to the low priority Remote Microphone’s priority input.
Do not connect the priority input and priority output if the priority order setting is not set. Connect the LINE OUT cables in
parallel. Refer to "Mixing Power Amplifier (WA-MA120N/240N) Connection-2" on page 6 and 7 for information about connecting
Remote Microphone to Mixing Power Amplifier (WA-MA120N/240N).

Connections between Mixing Power Amplifiers

Refer to the Operating Instructions of the Mixing Power Amplifier for details.

*1: Connect the ALL CALL BUS to be able to make all-line all-zone announcements.

Refer to the Operating Instructions of the Mixing Power Amplifier for the specifications for the cables.

*2: Set all the unit count switches for the total number of Mixing Power Amplifiers connected.

Example:

Turn all “3” ON if three units, including masters and slaves, are connected.

*3: Remove the slave’s short pin.

Important:

Do not remove the master’s short pin. If it is removed, audio will not be output.

*4: Connect INS.

Refer to the Operating Instructions of the Mixing Power Amplifier for the specifications for the cables.