Die cut supply requires no sensor adjustment.

1.

Do one of the following:

For black mark supply, turn the sensor adjustment knob
counterclockwise until it stops. Do not force the knob.

For feed apertures, turn the sensor adjustment knob
counterclockwise until it stops. Then turn the knob
clockwise as determined below.

Measure from the edge of the supply to the center of
the aperture.

Subtract 1/8 inch (3.1 mm) from the measurement.

Multiply the result by 36 (if you are measuring in milli-
meters, multiply by 1.41).

For example, if the measurement to the aperture center
is 3/8 inch (9.5 mm), turn the knob 9 turns to center the
sensor.

2.

Close the front panel.

Sensor
Adjustment
Knob

L

o

ad
ing

S
u

pp
lies

2. Loading Supply

2-19