Console port (outlined in red), Rear panel connectors and switches, Power connector – Patton electronic G.SHDSL INTEGRATED 3086 User Manual

Page 21: Ac universal power supply 48 vdc power supply

Advertising
background image

Model 3086 G.SHDSL IAD overview

21

Model 3086 G.SHDSL Integrated Access Device User Guide

1 • General Information

Console port (outlined in red)
The unshielded RJ-45 RS-232 console DCE port (EIA-561) with the pin-out listed in the following table:

Rear panel connectors and switches

On the rear panel from left to right are the following:

•

Power input connector

•

Ethernet connector

•

MDI-X switch

•

TDM port. V.35 (3086/C), X.21 (3086/D), T1/E1 (3086/K)

•

Line connector

Power connector

AC universal power supply.

The Model 3086 offers internal or external AC power supply options.

•

The internal power supply connects to an AC source via an IEC-320 connector (100–240 VAC, 200 mA,
50/60 Hz)

•

The external power supply connects to an external source providing +5 VDC via a barrel-type connector

48 VDC power supply.

•

Rated voltage and current: 36–60 VDC, 400 mA

•

Fuse rating: 250 Volts, 400 mA, time delay

Pin No. Signal Direction Signal Name

1

Out

DSR

2

Out

CD

3

In

DTR

4

—

Signal Ground

5

Out

RD

6

In

TD

7

Out

CTS

8

In

RTS

Connect the equipment to a 36–60 VDC source that is electri-
cally isolated from the AC source. The 36–60 VDC source is to
be reliably connected to earth.