Panasonic WV-NS202 User Manual

Page 47

Advertising
background image

47

Configure the settings relating to the alarm out connector

Click the [Alarm] tab on the "Alarm setup" page. (

☞ page 15)

Alarm output terminal setup

The settings relating to the alarm out connector can be configured in this section. The settings for the alarm output
terminal can be configured only when "Alarm output" is selected for "Terminal alarm 2" of "Alarm setup". Refer to
pages 43, 44 and 46 for further information about the settings relating to the alarm, the camera action at an alarm
occurrence and the alarm image.

[Alarm output

setup

]

Select "ON" or "OFF" to determine whether or not to
output the alarm signals to the alarm output terminal
when an alarm is detected.
Default: OFF

[External terminal output setup]
Select "Latch" or "Pulse" for the alarm output terminal at
an alarm occurrence.
Latch: When an alarm is detected, the alarm output ter-

minal will be in the state selected for "Alarm output"
until the alarm occurrence indication button is
clicked.

Pulse: When an alarm is detected, the alarm output ter-

minal will be in the state to the "Alarm output" setting
for the period set for "Pulse width".

Default: Latch

[Alarm output]
Select "Open" or "Close" to determine whether to open
or close the alarm output terminal when outputting the
alarm signals.
OPEN: The alarm output terminal will open when out-

putting the alarm signals. (Normally close)

CLOSE: The alarm output terminal will close when out-

putting the alarm signals. (Normally open)

Default: OPEN

Note:

When "OPEN" is selected, the alarm signal will be
output for around 20 seconds when the power of the
camera is turned on.

[Pulse width]
When "Pulse" is selected for "Alarm output", select an
alarm output terminal duration from the following.
Available pulse width: 1 - 120 sec
Default: 1 sec

AUX name

The names of "AUX", "OPEN" and "CLOSE" on the
"Live" page can be changed.

[AUX (Up to 10 characters)]
Enter the name for "AUX" on the "Live" page.

[OPEN (Up to 5 characters)]
Enter the name for "OPEN" of "AUX" on the "Live" page.

[CLOSE (Up to 5 characters)]
Enter the name for "CLOSE" of "AUX" on the "Live"
page.

Advertising