Adjustment

11 - 5

11.

04.04

Pre-adjusting the needle height

Requirement
With the needle bar at BDC, the distance between the needle bar and the needle plate
must be

15 mm.

● Move needle bar

1 (screw 2) in accordance with the requirement without moving it

laterally.

Fig. 11 - 04

1

2

15 mm