Adjustment

11 - 15

11.

04.13

Needle thread tension release

Requirement
With the presser foot raised, both of the tension discs must be at least

0.5 mm apart.

The clearance of 0.5 mm is a minimum and can increase to more than

1 mm

when using thick threads.

● Align pressure plate

1 behind tension carrier plate 2 in accordance with the requirement.

If the tension is correct, release pin

3 must not be under pressure.

Fig. 11 - 13

0.5 mm

3

2

1