Adjustment

11 - 21

11.

05.02

Tripping lever

Requirement
In needle rise position, the flattened pin of control lever

6 (see arrow) must fall slightly into

the track of control cam

7 when activating lever 8 is activated.

Fig. 11 - 18

● Screw out screw

1 and swing out connecting rod 2.

● Loosen screws

3 and 4.

● Bring the needle bar to needle rise position by turning the handwheel.
● Bring clamp

5 to rest on the right side of the housing.

● Keeping this position, move control lever

6 laterally in accordance with the requirement

and then press control lever

6 onto the bottom of the cam track.

● In this position, tighten screw

3.

● Carry out a check in accordance with the

requirement.

● Screw

4 remains loosened until the release trip is adjusted.