Procom VOR/ILS Analyzer EVS200 User Manual

Page 46

Advertising
background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

37

Chapter 3: Operation

Command AM2

command

function

AM2

<AM modulation depth (90 Hz)>

query of AM modulation depth (90 Hz)

The command AM2 reads the actual AM modulation depth (90 Hz) in the ILS mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM2 <CR>
am2 <CR>

e.g.

50% <CR/LF>

e.g.

50% <CR/LF>

Command AM3

command

function

AM3

<AM modulation depth (150 Hz)>

query of AM modulation depth (150 Hz)

The command AM3 reads the actual AM modulation depth (150 Hz) in the ILS mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

Query:

AM3 <CR>
am3 <CR>

e.g.

29.9% <CR/LF>

e.g.

29.9% <CR/LF>

Command PH

command

function

PH

<Phase 90/150 Hz>

query of Phase angle 90/150 Hz

The command PH reads the actual PHI value between 90 Hz and 150 Hz in the ILS mode.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

PH <CR>
ph <CR>

e.g.

119.9DEG <CR/LF>

e.g.

119.9DEG <CR/LF>