Procom VOR/ILS Analyzer EVS200 User Manual

Page 52

Advertising
background image

VOR/ILS Analyzer EVS200

0796.1800.02

E-8

43

Chapter 3: Operation

Command AF8

command

function

AF8

<AF-frequency ID>

AF-frequency ID query

The command AF8 reads the actual AF frequency (ID) in the ILS /VOR mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AF8 <CR>
af8 <CR>

e.g.

1020.0Hz <CR/LF>

e.g..

1020.0Hz <CR/LF>

Command AM8

command

function

AM8

<AM-modulation depth (ID)>

query of AM-modulation depth (ID)

The command AM8 reads the actual AM-modulation depth (ID) in the ILS / VOR mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM8 <CR>
am8 <CR>

e.g.

10.0% <CR/LF>

e.g.

10.0% <CR/LF>

Command AM9

command

function

AM9

<AM-modulation depth (voice)>

query of AM-modulation depth (voice)

The command AM9 reads the actual AM-modulation depth (voice 300 Hz to 3kHz) in the ILS / VOR
mode.

Prediction for reading out the data of the corresponding mode (VOR/ILS) is the
switching over to display2.

Example:

command from the controller

response of the VOR/ILS Analyzer EVS200

query:

AM9 <CR>
am9 <CR>

e.g.

09.6% <CR/LF>

e.g.

09.6% <CR/LF>