Iii. your power chair – Pride Mobility JET 3 User Manual

Page 20

Advertising
background image

20

www.pridemobility.com

Jet 3 Ultra

I I I . Y O U R P O W E R C H A I R

Electrical Components
The electrical components are located on the power base. The ammeter and the charger power cord receptacle are
located on the right side of the power base. The main circuit breaker is located on the front of the battery tray. The
controller connector and the motor connectors are located on the power pod, inside the power base. See figure 7.

Controller Connector: This is where the controller connects to the power base. Each controller uses a different
type of harness. Regardless of which type of controller is used, the harness must be secured to the seat assembly
and not allowed to drag on the floor.

Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batter-
ies and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent
damage to the motors and the electronics. If the circuit trips, allow your power chair to “rest” for approximately
one minute. Next, push in the circuit breaker button, turn on the controller, and continue normal operation. If the
main circuit breaker continues to trip repeatedly, contact your authorized Pride Provider.

Motor Connectors: This is where the controller connects to the motors. The motor connectors are color-coded with
red and yellow labels. The label color on the motor connector corresponds with the label color on the power pod.

Battery Connector: This is where the controller connects to the batteries.

MOTOR CONNECTORS

Figure 7. Jet 3 Ultra Electrical Components

BATTERY CONNECTOR

CONTROLLER
CONNECTOR

MAIN CIRCUIT BREAKER

Advertising