Parts and their functions, Front panel, Power switch cassette insertion slot eject button – Panasonic AJ-SD255 User Manual

Page 8: Control switch, Rec inhibit switch, Meter (full/fine) selector button, Monitor sel button, Headphone jack and volume control, Audio level control knobs, Audio level control selector switch

Advertising
background image

8

Parts and their functions

Front panel

Digital Video Cassette Recorder AJ-

SUPER

ON

OFF

TCG

REGEN

PRESET

EXT

INT

COUNTER

PF

PF1

PF2

PF3

DIAG

MENU

PUSH

SHTL/SLOW

TC

PRESET

METER

FULL/FINE

MONITOR SEL

RESET

UNITY VAR

INPUT SELECT

VIDEO

AUDIO

CH 1

CH 2

CH 1

CH 2

REC

PB

HEADPHONES

SEARCH

EJECT

POWER

REC INHIBIT

CONTROL

ON

ON

OFF

OFF

LOCAL

REMOTE

REC

PLAY

FF

REW

STOP

POWER switch

Cassette insertion slot

EJECT button

When this button is pressed, the tape is unloaded and the
cassette is ejected automatically a few seconds later.
When CTL display has been selected for the counter
display, the display is reset.
EJECT button operation can be enabled or disabled with
setup menu No. 115 (EJECT SW INH).

CONTROL switch

This is selected to control the unit from an external
source using the REMOTE connector.
REMOTE: Set to this position to control the unit using the

9-pin REMOTE connector and IEEE1394
AV/C commands.

LOCAL : Set to this position to control the unit using the

controls on the unit's operation panel.

REC INHIBIT switch

This switch is used to enable or disable recording on the
cassette tape.
ON:

Recording on the cassette tape is disabled
(inhibited).
In this state, the REC INH lamp lights on the display
panel.

OFF:

Recording on the cassette tape is enabled so long
as the accidental erasure prevention mechanism on
the cassette tape is set to enable recording.

METER (FULL/FINE) selector button

This button is used to select the scale display for the
audio level meter.
FULL mode

: The standard scale (–

∞ to 0 dB) is

selected.

FINE mode

: The scale in 0.5 dB increments is

selected. The

position indicates the

standard level of –20 dB (–18 dB). (See
page 11)

MONITOR SEL button

This button is used to select the audio signals which are
to be output to the AUDIO MON L and R connectors.
Each time the button is pressed, the audio signals to be
output to the AUDIO MON L or R connector are changed
in the following sequence.

Which signal is currently selected is displayed by the
lighting of the L or R lamp on the level meter display.

Headphone jack and volume control

When stereo headphones are connected to the
headphone jack, the sound can be monitored using the
headphones during recording or playback.

Audio level control knobs

These knobs are used to adjust the recording and
playback level of the PCM audio signals (CH1 and CH2).

The audio level control selector switch

is used to set

to variable or fixed level.
Note:
The level of the IEEE1394 digital input/output audio
signals cannot be adjusted.

Audio level control selector switch

UNITY: At this position, the audio signals are recorded or

played back at a fixed level regardless of the

position of the audio level control knobs

.

VAR: At this position, the audio signals are recorded or

played back at the level adjusted by the audio level

control knobs

.

Note:
When UNITY is selected, the recording and playback
levels both become UNITY (fixed level).

L :

[CH1] [CH1] [CH2] [CH1+CH2]

R : [CH2] [CH1] [CH2] [CH1+CH2]

Advertising