10 • maintenance – Pitney Bowes DM100i User Manual

Page 125

Advertising
background image

10-7

10 • Maintenance

SV62214 Rev. A

2. Separate wick from metal holder, clean the wick in plain water,

and rinse thoroughly.

3. Place the wick back in the hold er.
4. Reinstall the wick and holder assembly into moistener.
5. Reinstall the moistener. Push down on the blue re lease lever on

the moistener.

Removing and Cleaning the Moistener Wick and Holder

i

NOTE:

This procedure assumes you have done steps 1 to 7 from

the previous "Removing and Cleaning the Moistener Brush" section.

6. Slide the moistener back onto the machine. You should hear a

click as it engages.

Wick

Holder

Release
Lever

CLICK!

1. Pull up and remove the holder and wick from the moistener as

shown here.