Parameter setting, Parameters for function selection, Power on – Panasonic MINAS A3 Series User Manual

Page 14

Advertising
background image

144

Parameter Setting

Parameters for Function Selection

Parameter

No.

Setting

range

Parameter Name

Function/Description

Default setting is shown by [ ]

01

0 – 15

LED display at

power up

In the initial condition after turning ON the control power, the following data displayed

on the 7-segment LED can be selected.

Power ON

Setting of Pr01

Flashing during initialization
(about 2 seconds)

Setting

value

Description

0

[1]

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Positional deviation

Motor revolving speed

Torque output

Control mode

I/O signal status

Error cause/record

Software version

Alarm

Regenerative load ratio

Overload load ratio

Inertia ratio

Feedback pulse sum

Command pulse sum

External scale deviation

External scale feedback pulse sum

Motor auto recognition

See page 56 "Front Panel Key Operations and Display".

00

0 – 15

[1]

Axis address

In communications with a host device such as a personal computer that uses

RS232C/485 with multiple axes, you should identify to which axis the host accesses

and use this parameter to confirm axis address in terms of numerals.

• At power on, settings of the rotary switch ID on the front panel (0 – F) will be

programmed into parameters of the driver.

• Settings of Pr00 can be changed only by means of the rotary switch ID.

02

0 – 14

Control mode

Select the control mode of the servo driver.

0

[1]

2

3

4

5

6

7

8

9

10

11

12

13

14

Control mode

The 1st Mode

The 2nd Mode*1

Position control

Speed control

Torque control

Position

Position

Speed

Semi-closed control

Full-closed control

Hybrid control

Speed

Speed

High-stiff equipment

position control

Low-stiff equipment

position control

Low-stiff equipment

speed control

Second full-closed control

Speed control

Torque control

Torque control

External encoder control

Semi-closed control

The 1st

The 2nd

Closed

Open

C-MODE

10 ms or longer

10 ms or longer

Open

The 1st

*1 A special control mode focused on the full-closed

specification. For details, refer to “Full-Closed
Control” volume on Page 000.

*2 When composite mode (Pr02 = 3,4,5,9,10) is set,

you can switch the 1st and 2nd modes with the
control mode switch input (C-MODE).

<Caution>
Enter a command after 10ms or longer have passed
since C-MODE was entered.
Do not enter any command on position, speed or
torque.

Setting

value

Advertising