Connections and settings in torque control mode – Panasonic MINAS A3 Series User Manual

Page 15

Advertising
background image

145

[Connections and Settings in Torque Control Mode]

Connections and Settings in

Torque Control Mode

ZEROSPD input being ignored, it is determined that it is not speed

zero clamp state at all times.

ZEROSPD input has been enabled. If connection with COM- is

opened, speed command will be regarded as zero.

04

0 – 1

Overtravel input

inhibit

In the case of linear driving, in particular, to prevent mechanical damage due to

overtraveling of work, you should provide limit switches on both ends of the axis, as

shown below, whereby driving in a direction of switch action is required to be

inhibited.

<Cautions>
1. When you set 0 to Pr04 and do not connect both CCWL and CWL inputs to COM-

(off), abnormal condition in which limits are exceeded in both CCW and CW
directions is detected, and the driver will then trip due to “abnormal overtravel
input inhibit“.

2. You can set whether or not to activate the dynamic brake when slowdown occurs

because CCW or CW overtravel input inhibit has been enabled. For details, refer
to descriptions on Pr66 (DB deactivation at overtravel input inhibit).

CW direction

CCW direction

CCWL

CWL

Work

Servo Motor

Limit

Switch

Limit

Switch

Driver

Setting

value

0

[1]

Action

CCWL/CWL

Input

Enable

Disable

Input

CCWL

(CN X5-9 pin)

CWL

(CN X5-8 pin)

Connection with COM-

Connected

Open

Connected

Open

Normal condition in which the limit switch on

CCW side is not operating.

CCW direction inhibited, CW direction allowed

Normal condition in which the limit switch on

CW side is not operating.

CW direction inhibited, CCW direction allowed

Both CCWL and CWL inputs are ignored and they normally operate as no

overtravel inhibit being set.

Parameter

No.

Setting

range

Parameter Name

Function/Description

Default setting is shown by [ ]

07

0 – 9

Speed monitor

(SP) selection

The parameter selects/sets a relationship between voltage output to the speed

monitor signal output (SP: CN X5 43-pin) and the actual motor speed or command

speed.

Setting value

0

1

2

[3]

4

5

6

7

8

9

SP Signals

Motor Actual

Speed

Command

Speed

Relationship between Output Voltage Level and Speed

6V / 47 r/min

6V / 187 r/min

6V / 750 r/min

6V / 3000 r/min

1.5V / 3000 r/min

6V / 47 r/min

6V / 187 r/min

6V / 750 r/min

6V / 3000 r/min

1.5V / 3000 r/min

06

0 – 1

ZEROSPD input

selection

This sets switching of enable and disable of speed zero clamp input (ZEROSPD,

CNX5 26-pin).

Setting value

[0]

1

Function of ZEROSPD Input (26-pin)

Advertising