146

Parameter Setting

08

0 – 12

Torque monitor

(IM) selection

The parameter selects/sets a relationship between voltage output to the torque

monitor signal output (IM: CN X5 42-pin) and generated torque of the motor or

number of deviation pulses.

Setting value

[0]

1

2

3

4

5

6

10

11

12

IM Signals

Torque

No. of

Deviation

Pulses

Torque

Relationship between output level and torque or number of deviation pulses

3V / rated (100%) torque

3V / 31Pulse

3V / 125Pulse

3V / 500Pulse

3V / 2000Pulse

3V / 8000Pulse

Enabled under full-closed control (See P156

.)

3V / 200% torque

3V / 400% torque

09

0 – 5

TLC output

selection

The parameter allocates functions of output in torque limits (TLC: CN X5 40-pin).

Setting value

[0]

1

2

3

4

5

Remarks

For functional de-

tails of respective

outputs listed left,

refer to "Wiring to

Connector CN X5"

on page 78.

Functions

Output in torque limit

Output of zero-speed detection

Output of an alarm due to either of over-

regeneration/overload/absolute battery

Output of over-regeneration alarm

Output of overload alarm

Output of absolute battery alarm

0A

0 – 5

ZSP output

selection

The parameter allocates functions of zero speed detection output (ZSP: CN X5 12-pin).

Setting value

0

[1]

2

3

4

5

Remarks

For functional de-

tails of respective

outputs listed left,

refer to "Wiring to

Connector CN X5"

on page 78.

Functions

Output in torque limit

Output of zero-speed detection

Output of an alarm due to either of over-

regeneration/overload/absolute battery

Output of over-regeneration alarm

Output of overload alarm

Output of absolute battery alarm

0B

0 – 2

Absolute encoder

set up

Listed below are settings when you use the absolute encoder:

Setting value

0

[1]

2

Description

To use the absolute encoder as absolute.

To use the absolute encoder as incremental.

To use the absolute encode as absolute. In this case, multi-rotation

excess counter is ignored.

0C

0 – 2

Baud rate of

RS232C

Setting value

0

1

[2]

Baud Rate

2400bps

4800bps

9600bps

0D

0 – 2

Baud rate of

RS485

Setting value

0

1

[2]

Baud Rate

2400bps

4800bps

9600bps

Parameter

No.

Setting

range

Parameter Name

Function/Description

Default setting is shown by [ ]