Remote specifications – Panasonic BT-LH80WP User Manual

Page 32

Advertising
background image

32

REMOTE Specifications

(continued)

RS-232C terminal

Assignment of item priority levels

When both “MARKER1” and “MARKER2” are ON at the same time, “MARKER1” has priority. However, when
the display aspect is 4:3, the “MARKER1” aspect is 16:9, and the “MARKER2” aspect is 4:3, “MARKER2” is
displayed. In this case, the “MARKER2” background is controlled.

When “MARKER BACK HALF” and “MARKER BACK BLACK” are simultaneously activated, priority goes to
“MARKER BACK BLACK”.

When two or more of the following items - “INPUT SEL. VIDEO”, “INPUT SEL. VF”, “INPUT SEL. SDI” and
“INPUT SEL. YP

B

P

R

” - are simultaneously activated, priority goes to the last item activated.

Refer to the following diagram and lower right table for the RS-232C terminal pin arrangement and connections.
Please contact the vendor for information about detailed systems which used the RS-232C.

RS-232C Terminal (9P)

PC Side

(Straight)

BT-LH80W Side

Pin number Signal

Pin number Signal

1

N.C.

1

N.C.

2

RXD

2

TXD

3

TXD

3

RXD

4

DTR

4

DSR

5

GND

5

GND

6

DSR

6

DTR

7

RTS

7

CTS

8

CTS

8

RTS

9

N.C.

9

N.C.

RS-232C REMOTE operation method

Connectors and signal names

Connector: D-SUB 9-pin (female)
Signal name

Pin

number

Signal

name

Explanation

1

N.C.

Not connected

2

TXD

Transmission data

3

RXD

Reception data

4

DSR

Connected inside.

5

GND

Ground

6

DTR

Connected inside.

7

CTS

Connected inside.

8

RTS

Connected inside.

9

N.C.

Not connected

Communication Conditions

Signal level

Conforms to RS-232C

Synchro system

Tone pace synchro system

Transfer rate

9600 bps

Parity

None

Data length

8 bit

Stop bit

1 bit

Flow control

None

Command format

STX(02h) Command :

Data

ETX(03h)

• Commands are 3 characters following STX, finally

adding ETX.

• Add a : (colon) after the command as required, and

add the data.

Response formats

1. Setting command response

STX(02h)

Command

ETX(03h)

2. Query command response

STX(02h)

Data

ETX(03h)

3. Error response

STX(02h)

Error code

ETX(03h)

Error code
ER001: Invalid command
ER002: Parameter error

Advertising