Interface, Setup menus, User menu – Panasonic AJ-SD930BE User Manual

Page 40

Advertising
background image

40 (E)

CONTENTS

Setup menus

The underlined items indicates the initial setting.

USER menu

<INTERFACE>

No./Item

Description

200

PARA RUN

This selects whether two or more VTRs are to
be operated in synchronization.

0000

DIS : No operation in synchronization

0001

ENA : Operation in synchronization

<Note>
When operating two or more VTRs in
synchronization, set all the VTRs to ENA.

202

ID SEL

This sets the ID information to be returned to
the controller.

0000

OTHER

0001 DVCPRO
0002

ORIG

<Notes>

O

ID information of any VTR except for the
DVCPRO’s is set in OTHER.

O

The ORIG setting should only be used when a
Panasonic controller (AG-A850 etc. sold
separately) is connected.

203

25P SEL

This selects whether the PARALLEL (25P)
connector functions when the CONTROL
switch has been set to REMOTE.

0000

OFF : Connector does not function.

0001

ON : Connector functions.

205

BAUD RATE

These settings are for selecting the RS-232C
communication speed (baud rate).

0000

300

0001

600

0002

1200

0003

2400

0004

4800

0005

9600

204

RS232C SEL

This selects whether the RS-232C connector
functions when the CONTROL switch has
been set to REMOTE.

0000

OFF : Connector does not function.

0001

ON : Connector functions.

206

DATA
LENGTH

These settings are for selecting the RS-232C
data length.
(Unit: bit)

0000

7

0001

8

207

STOP BIT

These settings are for selecting the RS-232C
stop bit length.
(Unit: bit)

0000

1

0001

2

201

9P SEL

This selects whether the REMOTE (9P)
connector functions when the CONTROL
switch has been set to REMOTE.

0000

OFF : Connector does not function.

0001

ON : Connector functions.

208

PARITY

These settings are for selecting the none, odd
or even for the RS-232C parity bit.

0000

NON :

Parity bit is not used.

0001

ODD:

An odd number of bits is used for the parity
system.

0002

EVEN:

An even number of bits is used for the parity
system.

No./Item

Description

209

RETURN ACK

These settings are for selecting whether the
ACK code is to be returned when a command
is received from RS-232C.

0000

OFF : ACK code is not returned.

0001

ON : ACK code is returned.

210

25P STBY
CMD

For selecting the method used to detect the
STANDBY COMMAND signal input at the
PARALLEL (25P) connector.

0000 OFF/ON :

Each time active signals are detected, the
STANDBY ON or STANDBY OFF mode is
selected alternately.

0001

ON :

When active signals are detected in the
STANDBY OFF mode, the unit is transferred to
the STANDBY ON mode.
Nothing happens if they are detected during an
operation in the STANDBY ON mode.

212

MASTER
PORT

SD955B

For selecting the remote control connector to
control the slave when the unit is used as the
master during deck-to-deck operations.

0000

IN/OUT : The IN/OUT connector is used.

0001

OUT : The OUT connector is used.

<Note>
This menu item takes effect only when the
CONTROL switch has been set to the LOCAL
position.

211

LOCAL 25P

This selects whether the PARALLEL (25P)
connector is to function when the CONTROL
switch is at the LOCAL position.

0000

OFF : Connector does not function.

0001

ON : Connector functions.

Advertising
This manual is related to the following products: