Control interface for external devices, Tally/gpi – Panasonic AW-RP50N User Manual

Page 37

Advertising
background image

37

Control interface for external devices

TALLY/GPI

TALLY IN 1 to TALLY IN 5 are contact input ports which are used to light the unit’s
tally indicators (above the CAMERA STATUS/SELECTION buttons).
The tally lamps light with contact input.
GPI IN 1 to GPI IN 4 are contact input ports which are used to control the unit from
an external source.
GPI OUT 1 to GPI OUT 4 are open output ports which are used to output the
statuses to an external source.

(D-sub 15-pin, female, inch thread)

8

1

15

9

Pin No.

Signal

Description of signal

Operation

1

TALLY IN 1

CAM1 tally input

Contact input

9

TALLY IN 2

CAM2 tally input

2

TALLY IN 3

CAM3 tally input

10

TALLY IN 4

CAM4 tally input

3

TALLY IN 5

CAM5 tally input

11

GND

Ground

4

GPI IN 1

Preset input 1

Contact input

12

GPI IN 2

Preset input 2

5

GPI IN 3

Preset input 3

13

GPI IN 4

Panel lock

6

GPI OUT 1

Remote camera selection 0

Open collector output

14

GPI OUT 2

Remote camera selection 1

7

GPI OUT 3

Remote camera selection 2

15

GPI OUT 4

Alarm

8

NC

Not used

GND

GPI OUT

LED

Example of GPI OUT connections
Ensure that the conditions given below are satisfied.

Dielectric strength: Max. DC 24 V
Current:

Max. 50 mA

AW-RP50

(Max. voltage: 24 V)

(Max. current: 50 mA)

GND

GPI IN

TALLY IN

+3.3 V

Example of TALLY IN and GPI IN connections
Provide contact inputs.

AW-RP50

: The selection statuses (CAMERA STATUS/SELECTION buttons 1 to 5) of the remote cameras can be monitored at

GPI OUT 1 to GPI OUT 3.

CAMERA STATUS/SELECTION

button

Remote camera

selection 0

(GPI OUT 1)

Remote camera

selection 1

(GPI OUT 2)

Remote camera

selection 2

(GPI OUT 3)

1

On

Off

Off

2

Off

On

Off

3

On

On

Off

4

Off

Off

On

5

On

Off

On