1 rs232c port signals, Pin layout – Panasonic FP2 User Manual

Page 31

Advertising
background image

RS232C Port Wiring

FP2−CCU

4 − 3

4.1

RS232C Port Signals

4.1

RS232C Port Signals

Pin layout

Pin No.

Signal

Mnemonic

Signal direction

1

Frame Ground

FG

2

Send Data

SD

Unit → External device

3

Receive Data

RD

Unit ← External device

4

Request to Send

RS

Unit → External device

5

Clear to Send

CS

Unit ← External device

6

(Not used)

7

Signal Ground

SG

8

Receive Carrier Detect

CD

Unit ← External device

9

Equipment Ready

ER

Unit → External device

FG (Frame Ground)
This is connected to the FG terminal on the power supply unit, along with the connector

housing, through the backplane.
SD (Send Data)
This signal is used when data is being sent to a partner device. With the Computer

Communication Unit, the SD (green) LED among the operating status LEDs flashes if

the data has been sent properly.
RD (Receive Data)
This signal is used when data is being received from a partner device. With the Computer

Communication Unit, the RD (green) LED among the operating status LEDs flashes if

the data has been received properly.
RS (Request to Send)
This signal requests that data be sent from a partner device. With the Computer

Communication Unit, the RS signal is constantly on.
CS (Clear to Send)
This signal goes on when the partner device is ready to receive data.

With the FP2 Computer Communication Unit, input to this terminal is invalid, so no

connections are necessary.
SG (Signal Ground)
This signal provides a common reference potential for circuits connected to the

Computer Communication Unit and any external devices.

next page

9−pin internal

Advertising