Specifications

FP2−CCU

6 − 3

6.1

Specifications

6.1

Specifications

General Specifications

Item

Specifications

Ambient temperature

0 to 55 °C/32 to 131 °F

Storage temperature

–20 to +70 °C/– 4 to + 158°F

Ambient humidity

30 to 85 % RH (at 25°C non−condensing)

Storage humidity

30 to 85 % RH (at 25°C non−condensing)

Vibration resistance

10 to 55 Hz, 1 cycle/min.: double amplitude 0.75 mm (0.03 in.),

10 min. on 3 axes

Shock resistance

Min. 98 m/s

2

, 4 times on 3 axes

Noise resistance

1000 V

p−p

, 50 ns, 1 μs pulse widths (based on in−house measurements)

Operating condition

Free of corrosive gases and excessive dust

Computer Communication Unit Performance Specifications

Item

Specifications

Interface

Two RS232C ports

Transmission distance

Max. 15 m/49.212 ft

*1

Transmission speed (Baud rate)

19,200/9,600/4,800 bits/s, selectable using DIP switch

Communication method

Half duplex

Synchronous method

Start−stop synchronous method

Transmission code

ASCII

Transmission data format

Stop bit: 1−bit
Parity: Valid (odd)
Character bits: 7−bit/8−bit, selectable using DIP switch

Data transmission order

0 bit first in units of characters

End terminal code

CR (0DH)

Computer linking Message

Header (%) to terminator (CR) Once transmission rights from the

host computer are received, com-

Maximum message length Max. 118 characters/frame

(including “%” and “CR”)

host computer are received, com

munication is started. The commu-

nication protocol is MEWTOCOL−

COM.

Current consumption

60 mA or less (at 5 V DC)

Weight

Approx. 120 g/4.233 oz

*1: The value is given as 15 m/49.212 ft. in the specifications, but if used in an environment with a high noise level,

communication may be unstable. Check the conditions using the actual device.