Error messages (continued) – Panasonic AJ-SDd93 User Manual

Page 41

Advertising
background image

– 41 –

Error messages (continued)

Monitor display

Description

VTR operation

Corrective action

E-01
(LOW RF)

This appears when an envelope level
approximately one-third of the normal level
has been detected for more than one
second during playback or recording.

Clean the video heads.

E-02
(HIGH ERROR
RATE)

This appears when the error rate has
increased to the extent that correction or
interpolation was applied to either the video
or audio playback signals.

Clean the video heads.

O p e r a t i o n
continues.

O p e r a t i o n
continues.

Priority

Low

Monitor display

Description

VTR operation

E-29
FRONT LOAD
MOTOR

The unit switches to eject mode and if the cassette
fails to move up within 6 seconds, this error number
flashes on the display.
Note:
If the cassette does not move down inside the
machine even when 6 seconds have elapsed since
the cassette was inserted, the VTR is transferred to
the eject mode.

Set the POWER switch
to OFF and then to ON
again.

E-31
LOADING
MOTOR

If the unloading operation is not completed within 6
seconds, this error number flashes on the display.
Note:
When the loading operation is not completed within 6
seconds, the VTR is transferred to the eject
(unloading) mode.

Set the POWER switch
to OFF and then to ON
again.

E-20
DEW

If condensation is detected, the error number flashes
and the unit transfers to eject mode. The drum rotates
after the cassette is ejected to eliminate the
condensation.
Once the unit is released from condensation status,
the error message display is cleared and the VTR is
able to be used.
• If condensation is detected in the eject mode, the

drum starts rotating as soon as it is detected.

• If condensation is detected when the cassette has

been inserted, the drum rotation is stopped, and
after the tape is ejected, the drum starts rotating.

Leave the power on and
wait.

EJECT

STOP

STOP

E-35
SERVO CONTROL
ERROR

If there is no response from the servo microcomputer
for 1 second or more, this error number flashes on
the display.

Set the POWER switch
to OFF and then to ON
again.

STOP

E-37
SERVO COMM
ERROR

If 10 seconds or more elapses and the servo
microcomputer has not followed orders issued by the
system control microcomputer, this error number
flashes on the display.

Set the POWER switch
to OFF and then to ON
again.

STOP

E-51
FRONT LOAD
ERROR

If the take-up reel rotates without engaging for a
specific period of time during the start or end
processing operation while loading is underway (half
position), this error number flashes on the display.

Set the POWER switch
to OFF and then to ON
again.

STOP

Corrective action

Error messages