18

FPΣ (Sigma)

Specification tables

G

G E

E N

N E

E R

R A

A L

L S

S P

P E

E C

C II F

F II C

C A

AT

T II O

O N

N S

S

Rated operating voltage

24VDC

Operating voltage range

21.6 to 26.4VDC

Allowable no voltage time

4ms (at 21.6V), 10ms (at 26.4V)

Ambient temperature

0°C to +55°C

Storage temperature

-20°C to +70°C

Ambient humidity

30 to 85% RH

(Non-condensing)

Storage humidity

30 to 85% RH

(Non-condensing)

Vibration resistance

10 to 55Hz,

1 cycle/min.,

double amplitude of 0.75mm,
10min. on 3 axes

Shock resistance

98m/s

2

or more,

4 times on 3 axes

Noise humidity

1,000V (p-p)

with pulse

widths 50ns and 1µs

Operating condition

free from corrosive gasses
and excessive dust

II N

N P

P U

U T

T S

S P

P E

E C

C II F

F II C

C A

AT

T II O

O N

N S

S

Insulation method

Optical coupler

Rated input voltage

24VDC

Input voltage range

21.6 to 26.4VDC

Rated input current

3.5mA - 8mA depends on input no.
8 points/common (FPG-C24), 16 points/common (FPG-C32/C28),
32 points/common (FPG-XY64). Either the positive or
negative of input power supply can be connected to terminal

Min. ON voltage / Max. OFF current

19.2V / 3mA - 6mA depends on input no.

Max. ON voltage / Min. OFF current

2.4V / 1.3mA

Input impedance

3k - 6.8k depends on input no.

Response time

CPU:

1ms or less, 5µs (HSC, pulse catch, interrupt input)

Expansion:

0.2ms (OFF -> ON)
0.3ms (ON -> OFF)

Operating indicator

LED

O

O U

U T

T P

P U

U T

T S

S P

P E

E C

C II F

F II C

C A

AT

T II O

O N

N S

S -- T

T R

R A

A N

N S

S II S

S T

T O

O R

R O

O U

U T

T P

P U

U T

T T

T Y

Y P

P E

E

Item

FPG-C32 (NPN)

FPG-C28 (PNP)

Insulation method

Optical coupler

Output method

Open collector

Rated voltage range

5 to 24VDC

24VDC

Operating load voltage range

4.75 to 26.4VDC

21.6 to 26.4VDC

For Y0, Y1, Y3, Y4: 0.3A

For Y0, Y1, Y3, Y4: 0.5A

For Y2, Y5 to YF: 0.1A

For Y2, Y5 to YB: 0.3A

For Y0, Y1, Y3, Y4: 0.9A

For Y0, Y1, Y3, Y4: 1.5A

For Y2, Y5 to YF: 0.5A

For Y2, Y5 to YB: 0.7A

Output points per common

16 points/common

12 points/common

For Y0, Y1, Y3, Y4 at 15mA or lesss: <2µs
For Y2, Y5 and higher: < 0.2ms
For Y0, Y1, Y3, Y4 at 15mA or lesss: <8µs
For Y2, Y5 and higher: < 0.5ms

Power supply for driving internal circuit none
Operating indicator

LED

Phase fault protection

Thermal protection for Y2, Y5 and higher

Response time

OFF -> ON

ON -> OFF

Max. load current

Max. surge current

O

O U

U T

T P

P U

U T

T S

S P

P E

E C

C II F

F II C

C A

AT

T II O

O N

N S

S -- R

R E

E L

L A

AY

Y O

O U

U T

T P

P U

U T

T T

T Y

Y P

P E

E

Output type

Normally open (1 Form A)

Rated control capacity

2A 250VAC, 2A 30VDC (max. 4.5A/common)(resistive load)

Output points per common

8 points/ common
10ms or less
8ms or less

Mechanical life time

20 million operations or more

Electrical life time

100.000 operations or more

Surge absorber

21.6 to 26.4VDC (70mA)

Operating indicator

LED

OFF -> ON
ON -> OFF

Response time

Input points per common

20060227_FP_Sigma.qxd 15.02.2006 14:55 Uhr Seite 18

02/2006

Advertising