Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers
L22‐345 R1
9
Controller Operational Modes
MODE ENTRY
INDICATION
TEMPERATURE
SET POINT
EXIT
BOIL
OUT
With control initially off, toggle
the ON/OFF switch:
ON – OFF –
ON – OFF – Then ON
This sequence must be
performed within 3 seconds.
Power and HD
indicators are on. HFB
indicator flashes at 0.5
seconds rate until exit.
Fixed at 200°F
(93°C)
Press OFF to
exit.
MELT
Select MELT and then press
ON.
Melt may be bypassed by
pressing COOK.
Same as below except
fixed heat cycle.
ON
OFF
GAS
8 sec 22 sec
ELEC 4 sec 26 sec
No set point. HD is
suppressed if Vat is
greater than 250°F
(121°C).
Automatic
switch to
COOK after
temperature is
greater than
140°F (60°C)
or press OFF
to exit.
COOK
Press COOK and then press
ON.
Automatic entry after
completed MELT cycle.
Power indicator is on.
HD as required to
maintain Vat
temperature. HFB
indicator follows HD.
Knob setting
Press OFF to
exit.