Pitco Solstice and Solstice Supreme High Efficiency Gas Fryers 
 
 

 
L22‐345 R1 

Controller Operational Modes 

MODE ENTRY

INDICATION

TEMPERATURE

SET POINT

EXIT

BOIL
OUT

With control initially off, toggle
the ON/OFF switch:

ONOFF

ONOFF – Then ON

This sequence must be
performed within 3 seconds.

Power and HD
indicators are on. HFB
indicator flashes at 0.5
seconds rate until exit.

Fixed at 200°F
(93°C)

Press OFF to
exit.

MELT

Select MELT and then press
ON.

Melt may be bypassed by
pressing COOK.

Same as below except
fixed heat cycle.

ON

OFF

GAS

8 sec 22 sec

ELEC 4 sec 26 sec

No set point. HD is
suppressed if Vat is
greater than 250°F
(121°C).

Automatic
switch to
COOK after
temperature is
greater than
140°F (60°C)
or press OFF
to exit.

COOK

Press COOK and then press
ON.

Automatic entry after
completed MELT cycle.

Power indicator is on.
HD as required to
maintain Vat
temperature. HFB
indicator follows HD.

Knob setting

Press OFF to
exit.