Replacement

112

- ENGLISH

Maintenance

J

Procedure of lamp unit replacement

Attention

When the projector is mounted in the ceiling, do not work directly under the projector or put your face close to the projector.

z

The lamp unit and the lamp unit cover must be attached correctly and securely.

z

If the lamp unit is not installed smoothly, remove it and then install it again. If it is pushed in forcibly, its connector may be

z

broken.

Turn the main power OFF, following the

1 )

procedures described in “Powering off

the projector” (

Æ

page 41), disconnect

the power plug from the AC power

source, and wait for one hour or more.

Then check that the lamp unit has

cooled down.
Turn the “lamp unit cover fixing

2 )

screw” (1 piece) with a Phillips-head

screwdriver until it is fully loosened,

and then hold the “lamp unit cover”

securely and open it in the direction of

the arrow.

Use a Phillips screwdriver to loosen

3 )

the “Lamp unit cover fixing screw” (4

screws) for the lamp unit to be replaced

until the screws turn freely. Hold the

“Handle” of the “Lamp unit” and

gently pull the lamp unit out from the

projector.

Replace the new LAMP unit in correct

4 )

direction.

Use a Phillips screwdriver to securely

5 )

tighten the 2 “Lamp unit cover fixing

screw” for each lamp unit.
Close the “lamp unit cover” and

6 )

tighten the “lamp unit cover fixing

screw” (1 piece) securely with a

Phillips-head screwdriver in the

reverse order to Step 2).

Note

When the lamp unit is replaced, the duration of usage

z

time will be reset to “0”.

Lamp unit cover

fixing screw

Lamp unit cover

Lamp unit fixing screws

Lamp unit 1

Handle

Lamp unit 2

Lamp unit

installation guide

Groove for lamp unit installation guide

Groove for lamp unit installation guide