Technical Information

ENGLISH -

115

Appendix

Technical Information

PJLink protocol

The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform

projector setting and projector status query operations from a computer.

Control commands

J

The following table lists the PJLink protocol commands that can be used to control the projector.

Command

Control details

Notes

POWR

Power supply control

Parameters

0 = Standby

1 = Power ON

POWR ?

Power supply status query

Parameters

0 = Standby 1 = Power ON

2 = Cool-down in progress 3 = Warm-up in progress

INPT

Input selection

Parameters

11 = RGB1 12 = RGB2 21 = VIDEO

22 = S-VIDEO 31 = DVI-D 32 = HDMI

33 = SDI (PT-DZ110XE/PT-DS100XE only)

INPT ?

Input selection query

AVMT

Shutter control

Parameters

30 = Shutter mode off (picture mute canceled)

31 = Shutter mode on (picture mute)

AVMT ?

Shutter mode query

ERST ?

Error status query

Parameters

1st byte : Indicates fan errors, range 0 - 2

2nd byte : Indicates lamp errors, range 0 - 2

3rd byte : Indicates temperature errors, range 0 - 2

4th byte : Indicates cover open errors, range 0 - 2

5th byte : Indicates filter errors, range 0 - 2

6th byte : Indicates other errors, range 0 - 2
Definitions for each value from 0 to 2 are as follows.

0 = No error known 1 = Warning 2 = Error

LAMP ?

Lamp status query

Parameters

1st digits (1 - 5 digits) : Lamp 1 cumulative operating time

2nd digit : 0 = Lamp 1 off, 1 = Lamp 1 on

3rd digits (1 - 5 digits) : Lamp 2 cumulative operating time

4th digit : 0 = Lamp 2 off, 1 = Lamp 2 on

INST ?

Input selection list query

The following are returned as parameters.

“11 12 21 22 31 32” (PT-DW90XE only)

“11 12 21 22 31 32 33” (PT-DZ110XE/PT-DS100XE only)

NAME ?

Projector name query

The name set for [PROJECTOR NAME] in [NETWORK SETUP] is

returned.

INF1 ?

Manufacturer name query “Panasonic” is returned.

INF2 ?

Model name query

“DZ110XE”, “DS100XE” or “DW90XE” is returned.

INF0 ?

Other information query

Information such as version number is returned.

CLSS ?

Class information query

“1” is returned.

PJLink security authorization

J

When using PJLink with security authorization, either of the password set for administrator privileges and the

password set for user privileges with Web browser control can be used as the password for PJLink.

When using PJLink without security authorization, set use without the password for administrator privileges

and the password for user privileges of Web browser control.

For specifications regarding PJLink, refer to the Japan Business Machine and Information System

z

Industries Association website.

URL http://pjlink.jbmia.or.jp/