If your application requires that you use a prepolarized microphone with a
microphone preamplifier, contact Brüel and Kjær.

Custom Cabling

National Instruments offers cables of different lengths for the BNC-2140
accessory to connect your analog I/O signals to the DSA devices. National
Instruments recommends that you not develop your own cabling solution
due to the high-density connector that is required and the necessity to
maintain high signal integrity.

If your application requires you to develop your own cable, use the
following guidelines:

Use shielded twisted-pair wires for each differential analog input or
output channel pair. Since the signals are differential, using this type of
wire yields the best results.

When connecting the cable shields, be sure to connect the analog input
grounds to the AIGND pins and the analog output grounds to the
AOGND pins. For a connector pinout description refer to Table 3-2 in
Chapter 3,

Signal Connections

.

You can create your own accessories by using a 68-pin very high
density cable interconnect (VHDCI) receptacle header using AMP
68-position right-angle PWB receptacle header 787254-1.

Recommended manufacturer part numbers for the 68-pin mating
connector (for the cable assembly) are as follows:

AMP 68-position cable straight plug, part number 787131-3

AMP 68-position backshell with jackscrews, part number