2 digital audio data format control, 5 digital signal-processing features, 1 equalizer – NXP Semiconductors TFA9812 User Manual

Page 16: 1 equalizer options, 2 equalizer band function, Tfa9812, Nxp semiconductors

Advertising
background image

TFA9812_2

© NXP B.V. 2009. All rights reserved.

Preliminary data sheet

Rev. 02 — 22 January 2009

16 of 66

NXP Semiconductors

TFA9812

BTL stereo Class-D audio amplifier with I

2

S input

In I

2

C control mode the following sample frequency f

s

can be used: 8 kHz, 11.025 kHz,

12 kHz, 16 kHz, 22.05 kHz, 24 kHz, 32 kHz, 44.1 kHz, 48 kHz, 64 kHz, 88.2 kHz, 96 kHz,
128 kHz, 176.4 kHz or 192 kHz. The I

2

C control for f

s

selection can be found in

Section 9.5.7

.

In Legacy control mode the following sample frequencies (f

s

) can be used: 32 kHz,

44.1 kHz or 48 kHz.

8.4.2 Digital audio data format control

The BCK-to-WS and MCLK-to-WS frequency ratios are automatically detected, so no
control settings need to be configured for these.

In I

2

C control mode all the formats listed in

Table 12

are supported. The appropriate I

2

C

controls for selecting the supported formats can be found in

Section 9

. In the Legacy

control mode only a subset of the supported formats can be used. These are shown in

Table 12

and the required pin control is given in

Table 13

.

See

Section 8.2.1

for details of how to enable Legacy control mode.

8.5 Digital signal-processing features

8.5.1 Equalizer

8.5.1.1

Equalizer options

The equalizer function can be bypassed and the equalizer can be configured to either a
5-band or 10-band function. These settings are for both audio channels simultaneously.

There are 20 bands in the equalizer. These are distributed as follows:

Bands A1 to A5 are bands 1 to 5 of output 1 (used in 5-band and 10-band
configuration).

Bands B1 to B5 are bands 1 to 5 of output 2 (used in 5-band and 10-band
configuration).

Bands C1 to C5 are bands 6 to 10 of output 1 (used in 10-band configuration only).

Bands D1 to D5 are bands 6 to 10 of output 2 (used in 10-band configuration only).

In I

2

C control mode each band can be configured separately using I

2

C register settings.

In Legacy control mode the equalizer is bypassed.

8.5.1.2

Equalizer band function

The shape of each parametric equalizer band is determined by the three filter parameters:

(Relative) center frequency

.

Quality factor Q.

Gain factor G.

Table 13.

Digital audio data format selection in Legacy control mode

SCL/SFOR pin value

Interface formats (MSB-first)

0

I

2

S

1

MSB-justified

ω

2

π

f

c

f

s

(

)

=

Advertising