6 overdissipation protection, 7 window protection, 8 lock protection – NXP Semiconductors TFA9812 User Manual

Page 25: 9 underfrequency protection, 10 overfrequency protection, Table 20, Tfa9812, Nxp semiconductors

Advertising
background image

TFA9812_2

© NXP B.V. 2009. All rights reserved.

Preliminary data sheet

Rev. 02 — 22 January 2009

25 of 66

NXP Semiconductors

TFA9812

BTL stereo Class-D audio amplifier with I

2

S input

8.7.6 Overdissipation protection

When the output current of the power amplifiers exceeds a current value of 3 A and the
temperature is above 140

°

C, overdissipation protection is activated and the device enters

Sleep mode. A restart will be initiated automatically when the two overdissipation
conditions are both changed to ‘false’.

Overdissipation is flagged by a low DIAG pin and by a high DIAG I

2

C status bit, see

Section 9.5.10

.

Under normal conditions thermal foldback prevents overdissipation protection from being
triggered. I

2

C settings remain valid.

8.7.7 Window protection

Window protection is a feature for protecting the device against shorts from the outputs to
the ground or supply lines. If during power-up one of the outputs is shorted to V

SSPx

or

V

DDP

, power-up does not proceed any further. The trigger levels for these conditions are:

OUTxx > V

DDA

1 V, or

OUTxx < REFA + 1 V.

The WP alarm is flagged by a low DIAG pin and by a high DIAG I

2

C status bit, see

Section 9.5.10

.

8.7.8 Lock protection

When the selected clock input source (MCLK, BCK or crystal) stops running, the TFA9812
is able to detect this and set the output stages to 3-state mode. Without this protection
peripheral devices in an application might be damaged.

The PLL lock indication is an I

2

C reading and will be ‘false’ in the event of a clock

interruption, see

Section 9.5.10

.

8.7.9 Underfrequency protection

UFP sets the output stages to 3-state mode when the clock input source is too low. The
PWM switching frequency can becomes critically low when the clock input source is lower
than specified. Without UFP peripheral devices in an application might be damaged.

The status of the UFP is shown in I

2

C reading register, see

Section 9.5.10

.

8.7.10 Overfrequency protection

OFP sets the output stages to 3-state mode when the clock input source is too high. The
PWM controller can become unstable when the clock input source is higher than
specified. Without OFP peripheral devices in an application might be damaged.

The status of the OFP is shown in I

2

C reading register, see

Section 9.5.10

.

Table 20.

Undervoltage trigger levels

Pin name

UVP level

DIAG pin (protection active)

Min

Max

V

DDA

7 V

< 8 V

LOW

V

DDA(3V3)

1.6 V

< 3 V

-

Advertising