Special conditions for marine applications – National Instruments NI 9426 User Manual

Page 5

Advertising
background image

© National Instruments Corp.

5

NI 9426 Operating Instructions and Specifications

Special Conditions for Hazardous Locations Use in Europe

This equipment has been evaluated as Ex nA IIC T4 equipment
under DEMKO Certificate No. 07 ATEX 0626664X. Each module
is marked

II 3G and is suitable for use in Zone 2 hazardous

locations. If you are using the NI 9426 in Gas Group IIC hazardous
locations or in ambient temperatures of –40 °C

≤ Ta ≤ 70 °C, you

must use the device in an NI chassis that has been evaluated as
EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.

Special Conditions for Marine Applications

Some modules are Lloyd’s Register (LR) Type Approved for
marine applications. To verify Lloyd’s Register certification, visit

ni.com/certification

and search for the LR certificate, or

look for the Lloyd’s Register mark on the module.

Caution

To meet radio frequency emission requirements

for marine applications, use shielded cables and install
the system in a metal enclosure. Suppression ferrites
must be installed on power supply inputs near power
entries to modules and controllers. Power supply and
module cables must be separated on opposite sides of the
enclosure and must enter and exit through opposing
enclosure walls.