National Instruments NI 9426 User Manual
Page 7

© National Instruments Corp.
7
NI 9426 Operating Instructions and Specifications
Each channel has a DI pin to which you can connect a digital input
signal. The NI 9426 has four supply pins, V
sup
, that are internally
connected to the isolated reference of the module.
The NI 9426 has sourcing inputs, meaning the DI pin sources
current from V
sup
to the sinking output device. The NI 9426
internally limits current signals connected to DI. For more
information about input current levels, refer to the
section.
You can connect 2-, 3-, and 4-wire sinking-output devices to
the NI 9426. A sinking-output device provides a path from the
DI pin to a voltage below V
sup
. An example of a sinking-output
device is an open collector NPN.
Connect the sinking-output device to the DI pin of the NI 9426.
Connect the positive power supply lead of the external device to the
V
sup
pin. Refer to Figure 2 for an illustration of connecting a device
to the NI 9426.