Rs-232c, Continued – NEC 50XC10 User Manual

Page 27

Advertising
background image

English-24

RS-232C

- continued

Th

e following control sequence is used for a single monitor

When using the following control commands, all of the daisy-chained monitors
can be controlled at the same time from the primary monitor. However, reply and
status commands will only pertain to the primary monitor, and not to the secondary
monitors.

1) Interface

PROTOCOL

RS-232C

BAUD RATE

9600 [bps]

DATA LENGTH

8 [bits]

PARITY BIT

NONE

STOP BIT

1 [bit]

FLOW CONTROL

NONE

2) Control command diagram

Th

e command is structured by the address code, function code, data code and end

code. Th

e length of the command is diff erent for each function.

Address Code

Function Code

Data Code

End Code

HEX

30h 30h

Function

Data

0Dh

ASCII

'0' '0'

Function

Data

[Address code] 30h 30h (In ASCII code,

'

0

'

'

0

'

) fi xed.

[Function code] A code of each fi xed control move.

[Data code]

A code of each fi xed control data (number) and

not

always

indicated.

[End code]

0Dh (In ASCII code,

'

'

) fi xed.

To control multiple monitors that are daisy-
chained together please use the extended control
command.

Advertising